Sentence Monitor - Furuno FAR-2228-NXT Operator's Manual

Hide thumbs Also See for FAR-2228-NXT:
Table of Contents

Advertisement

Tested item
[MTR]
[TEMP]
(FAR-
[12V]
2018/
[MOTOR CURRENT]
2028-
MARK-2)
[MOTOR VOLTAGE]
[MOTOR ROT SPEED] 0 (STBY)/24/36/43
[ERROR STATUS]
[MAG HEATER VOL]
[MAG HEATER CUR]
[50V]
[PM]
[12V]
[PLL STATUS]
6.8

Sentence Monitor

You can check which sentences input to the radar.
1. Open the [MAIN MENU].
2. Select [9 INITIAL SETTINGS].
3. Select [7 TESTS].
4. Select [3 SENTENCE MONITOR].
5. Select the item you want to check.
All sentences input to the radar for the selected item
appear on the screen. Press the F3 key to save the
sentence information to the SD Card.
Press the F4 key to save a screenshot to the SD Card.
Note: If a SD Card is not connected to the Processor Unit, you cannot save sen-
tence information or screenshots.
6. Press the F1 key to close the sentence information.
7. Repeat steps 5 and 6 to view other sentence information as required.
8. Close the menu.
6. MAINTENANCE, TROUBLESHOOTING
Normal value or Description
Magnetron Radar
Ambient Temperature: less than +30 °C
9 to 15 V
• X-Band, 24 rpm: 0.8 A
• X-Band, 42 rpm: 1.2 A
43 to 53 Volts (33 to 53 volts for antenna units installed on the
foremast.)
Blank indicates no errors. When an error is found, the relevant er-
ror code appears.
• 12 kW, STBY/S1/S2:
7.85 to 8.75 V
• 12 kW, M1/M2/M3/L:
6.55 to 7.45 V
• 25 kW, STBY/S1/S2:
6.75 to 7.65 V
• 25 kW, M1/M2/M3/L:
5.45 to 6.35 V
0.485 to 0.655 A
49 to 50.4 V
9 to 15 Volts
For X-Band (with board revision
number 1 or earlier) and S-Band
(with board revision number 0):
UNLOCK
For X-Band (with board revision
number 2 or later) and S-Band
(with board revision number 1 or
later):
• PM activated: LOCK
• PM inactive: UNLOCK
Solid State Radar
-
-
-
-
• PM activated: LOCK
• PM inactive: UNLOCK
6-13