3. TARGET TRACKING (TT)
3.15.2

How to acknowledge the TT collision alarm

Press the ALARM ACK key on the control unit, or select the [ALERT] box with the
trackball then left-click to acknowledge the alarm and silence the buzzer. The alert
"CPA/TCPA" remains in the Alert Box until the dangerous situation is gone or you in-
tentionally terminate target tracking. The symbol and vector stop flashing and are dis-
played in a solid red color.
Note: When the "CPA/TCPA" alert is generated the AIS display is automatically
turned on.
3.16

Acquisition Zone

The acquisition zone functions both to alert you targets in a specific area and acts as
an automatic acquisition area when automatic target acquisition is active. Any targets
entering the zone will be automatically acquired.
When a target enters an acquisition zone, the buzzer sounds and "TT NEW TARGET"
or "AIS NEW TARGET" appears (in yellow-orange) in the Alert Box. The symbol of the
offending target is red and flashing. Further, the AIS display is automatically turned on
if it is off.
There are two types of acquisition zones available, arc and polygon, however, AZ1
can only be set as an arc.
Note: The acquisition zones are disabled when the setting for [2 AZ/ALR SELECT] in
the [ACQUISITION ZONE] menu is set to [TARGET ALARM ZONE].
3.16.1

How to enable the acquisition zones

1. Open the menu.
2. Select [5 TT•AIS].
3. Select [2 ACQUISITION ZONE].
4. Select [2 AZ/ALR SELECT].
5. Select [ACQUISITION ZONE].
6. Close the menu.