Ethernet Receiver 2 Options - DSC TL280LEX(R) Manual

Internet and lte/hspa dual-path alarm communicator, lte/hspa alarm communicator, hspa cellular alarm communicator , internet and hspa dual-path alarm communicator , internet alarm communicator
Table of Contents

Advertisement

NOTE: If Ethernet receiver 1 and cellular receiver 1 are programmed as the same receiver (IP and port number are
identical), Ethernet receiver 1 account code will be used.
[102] Ethernet Receiver 1 DNIS
Default (000000)
The Dialed Number Information Service (DNIS) is used in addition to the account code to identify the communicator module
at the central station. Valid range: 000000 - 099999. Value is entered as a leading 0 followed by the 5-digit DNIS.
[103] Ethernet Receiver 1 Address
Default (127.000.000.001)
The default address enables the communicator to operate in Unattended mode.
Unattended mode is used when a receiver is not available and the unit is required to perform DLS sessions. Typically used
where the customer programs the control panel daily due to access control and still wants to receive alarms without buying
extra hardware (receiver) or software.
NOTE: When a valid IP address has been programmed, Ethernet receiver 1 is enabled and will communicate events over
the Ethernet channel.
Ethernet receiver 1 and cellular receiver 1 may be configured to communicate to the same central station receiver. To con-
figure the device to operate using this common receiver mode functionality, program Ethernet receiver 1 and cellular
receiver 1, IP address and port number with identical values.
NOTE: When operating in common receiver mode, Ethernet receiver 1 account code will be used for Ethernet and cellular.
[104] Ethernet Receiver 1 UDP Remote Port
Default (0BF5/3061)
This section determines the UDP remote port of Ethernet receiver 1. Valid range: 0000 - FFFF.
[105] Ethernet Receiver 1 UDP Local Port
Default (0BF4/3060)
Use this section to set the value of the UDP local outgoing port. Set the value of this port when the installation is located
behind a firewall and must be assigned a particular port number as determined by the central station system administrator.
Valid range: 0000 - FFFF.
[106] Ethernet Receiver 1 Domain Name
Default (   )
Enter the domain name as 32 ASCII characters.
[107] Ethernet Receiver 1 Supervision Interval
Default (0087/135 seconds)
The supervision interval is only valid if the supervision has been enabled for Ethernet receiver 1 in section [100]. The
receiver supervision interval determines the delay, in seconds, between each heartbeat signal sent to the central station
receiver. If the interval programmed is less than 10 seconds (000A) then supervision is disabled. The valid range for this
section is 000A – FFFF seconds.
NOTE: This supervision interval programmed in the central station receiver must be 65s longer than the interval pro-
grammed in the communicator to ensure stable operation.

Ethernet Receiver 2 Options

[110] Ethernet Receiver: Options
Option 1: Ethernet Receiver 1 Enabled – Default ON/OFF
ON: Ethernet receiver 2 is enabled.
OFF: Ethernet receiver 2 is disabled.
Option 2: Ethernet Receiver 2 Supervision Enabled – Default OFF
ON: Ethernet receiver 2 is supervised and heartbeats are sent to Ethernet receiver 2 based on the supervision interval pro-
grammed in section [117].
OFF: Ethernet receiver 2 is not supervised. When disabled, a commercial heartbeat is sent to the receiver once per hour,
regardless of the supervision type selected, residential or commercial.
[111] Ethernet Receiver 2 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between transmitters. The account code is used when trans-
mitting heartbeat signals to the central station receiver. Signals received from the control panel will use the control panel
account number. Valid range: 0000000001- FFFFFFFFFE. Programming all 0's or all F's will cause a module configuration
trouble (yellow LED=12 flashes).
NOTE: If both Ethernet receiver 2 and cellular receiver 2 are the same receiver (IP and port number are identical), Ethernet
receiver 2 account will be used for Ethernet and cellular.