6-4.

Using Manual Mode

8
1 Auto-Set Button
Press to turn Auto-Set On or Off.
2 Pulse Button
Press to turn Pulse On or Off..
3 Set-Up Button
Press Setup to optimize arc performance or
to add timers to weld sequence.
4 Program Button
2
1
3
4
5
Press Program to save favorite weld pro-
grams, up to four programs per weld proc-
ess. See Section 6-7.
5 P. Chart Button
Press to access electronic parameter chart.
See section 6-8.
6 Jog Button
Feed wire without turning on weld output
and energizing gas solenoid.
7 Arc Control Button
6
7
9
Reference Inductance Control in Section 6-5
when using Manual MIG mode. Reference
Arc Control in Section 6-10 when using
Pulse MIG Manual mode.
8 Left Knob
Use left knob to adjust voltage in MIG mode
or arc length in Pulsed MIG mode.
9 Right Knob
Use right knob to adjust wire feed speed
ON
OFF
279061-E
OM-288360 Page 43

Advertisement