Wiring Optional 240 Volt Plug (119172) For Connection To Miller Welder/Generator With Split-Phase 240 Volt Auxiliary; Power - Miller Millermatic 355 Owner's Manual

Table of Contents

Advertisement

5-7.
Wiring Optional 240 Volt Plug (119172) For Connection To Miller Welder/Generator
With Split-Phase 240 Volt Auxiliary Power
Plug Front View
3
5
6
allen_wrench
pliers
needlenose
tools/
solderiron
flathead
knife
steelbrush
torque screwdriver
torque wrench
OM-288360 Page 22
4
240V
1
allen_set
knife
heavy-duty workclamp
stripcrimp
philips head
wrench
nutdriver
socket wrench
drill
2
3
4
7
5
6
8
7
tools/
9
8
flathead
philips head
1
10
11
steelbrush
Ref. 120 813-D / 907734
light-duty workclamp
crescent wrench
chippinghammer
1 Input And Grounding Conductors
2 Plug wired for 240 Volt, 2–wire Load
3 Neutral (Brass) Terminal and Prong (Not
Used)
4 Load 1 (Brass) Terminal and Prong
5 Load 2 (Brass) Terminal and Prong
6 Ground (Brass) Terminal and Prong
7 Black and White Input Conductors
8 Green
or
Green/Yellow
Conductor
9 Red Input Conductor
10 Insulation Sleeving
11 Electrical Tape
Insulate and isolate red conductor as shown.
Always connect green or green/
yellow wire to ground terminal,
never to a load terminal. Connect
black (L1) and white (L2) wires to
load terminals.
wrench
crescent wrench
nutdriver
chippinghammer
wirecutter
greasegun
filterwrench
Ground
frontcutter

Advertisement