6-11. System

1
3
From the system setting screen, the opera-
tor can enable the Trigger Program Select
feature, adjust the amount of time that the
Process Select screen is displayed, enable
Program Locks and Limits, view system
software information, restore the unit back
to factory default settings and select optional
welding guns.
Access the system information screen from
the manual MIG screen by pressing Setup
and then System.
1 Left Knob
2 Right Knob
Once in the Set-Up menu, press the system
button to access these system settings, ro-
tate the left knob to find a particular item,
and rotate the right knob to change the set-
ting or status.
Trigger Program Select
Trigger Program Select allows the operator
to change the programs by tapping the trig-
ger to eliminate the need to go back to the
machine to change the program on any
MIG, Push/Pull or Spoolgun to increase pro-
ductivity. Tapping the gun trigger the number
OM-288360 Page 50
4
of times to match the program that you want
to select. Tap one to select program 1, tap
twice to select program 2. Default setting is
disabled.
Aluma-Pro Type: (Only displayed when a
Miller XR Push/Pull gun is connected to the
Millermatic 355) - The Millermatic 355 is
compatible with 3 styles of Miller Push/Pull
guns and the MK Python gun. To optimize
arc performance, select the gun option that
matches the gun being used, XR-AlumaPro,
XR- AlumaPro Lite or XR-Pistol Pro. Only
when using the XR-AlumaPro Lite, does the
SUP value on the gun need to be entered in-
to the machine. For the XR-AlumaPro Lite
the SUP value setting is entered via the Set
Up menu. When using a MK Python, the Py-
thon is automatically detected, and the Alu-
ma-Pro Type option is not displayed in the
setup menu (Section 6-5). Default setting is
XR-Aluma-Pro.
10 Pin WFS Adjustment: (Only displayed
when a Push/Pull or Spoolgun is connected
to the Millermatic 355). — There are two op-
tions for controlling the wire feed speed. The
wire feed speed control can either be ad-
justed by the control in the handle of the gun
and the front panel of the machine or only at
ON
OFF
279061-E
the front panel and disable the control from
the gun. Default is Front Panel and Gun.
Process Set-Up Screen
To help you set up gas and polarity for the
machines multiple options, your Millermatic
355 features an intuitive color display
screen. The Process Setting screen illus-
trates how to properly configure the machine
for the different processes and wire combi-
nations. Default setting is enabled.
Process Setup Screen Timeout
The length of time that the Process Setup
screen is displayed. When enabled the time
can be adjusted from 1–30 seconds. Default
time is 3 seconds.
System Screen
The system screen displays four or five tabs
above the soft keys, depending on which
welding gun is connected.
3 Back
Press soft key to return to Set-Up screen.
4 Locks