6-8.
P. Chart (Electronic Parameter Chart)
3
When using Manual Mode, refer to the elec-
tronic parameter chart on the front display
for suggested starting parameters.
1 P. Chart Button
2 Wire/Gas Button
3 Left Knob
4 Right Knob
1
5 Load Button
To access the electronic parameter chart,
press the middle P. Chart button.
Press the middle Wire/Gas button to access
to wire, gas type and wire diameter.
Rotate left knob to select wire and gas type
being used.
ON
OFF
ON
OFF
5
2
ON
OFF
4
279061-E
5
Rotate right knob to select wire diameter
and press the Load button.
Rotate right knob to select material thick-
ness and press the Load button to save and
start welding.