Lipo/Liio/Life/Lihv/Lto/Nizn/User Discharge Setup; Regenerative To Input; Regenerative To Channel - iCharger 4512DUO User Manual

Dual balance charger/discharger/dc power
Table of Contents

Advertisement

1. Accelerated storage: accelerated storage via internal resistance correction. Tick Accelerated storage to activate
accelerated storage.
2. Storage Compensation is the compensation for the battery voltage fallback:
for storage charge, the actual storage voltage=Storage Cell Voltage + Storage Compensation;
for storage discharge, the actual storage voltage=Storage Cell Voltage - Storage Compensation.
LiPo/LiIo/LiFe/LiHV/LTO/NiZn/User Discharge Setup
Select Program→Discharge to enter Discharge setup interface.
1. The charger first discharges with constant current (CC) according to the user setting then turns to constant voltage
(CV) when it reaches the discharge voltage. In the CV phase the current gradually falls, and the charger will terminate
discharging when the current falls below the percentage of the configured discharge current.
2. Regenerative mode has three available settings: OFF, To input, To channel, see more details on Important Notes.
Regenerative To Input
When selecting to To input on Regenerative Mode, the energy discharged by the charger to the battery will be recovered to
the input port. For parameter settings, see Input Limit Setup
Regenerative To Channel
When selecting to To channel on Regenerative Mode, "Set..."button changes from inactive to its operational status, and
click to enter CHANNEL REGENERATIVE SETUP interface.
Dual Balance Charger/Discharger/DC Power
Storage Cell Voltage:
LiPo
3.7V/Cell-3.9V/Cell; default
LiIo
3.6V/Cell-3.8V/Cell; default
LiFe
3.1V/Cell-3.4V/Cell; default
LiHV
3.75V/Cell-4.1V/Cell; default
LTO
2.4V/Cell-2.6V/Cell; default
User
1.00V/Cell-4.5V/Cell; default
Storage Compensation:
0V/Cell-0.2V/Cell; Default: 0.01V/Cell
Discharge Current:
0.05A-45A; default: 2A
Discharge Voltage:
LiPo
3V/Cell-4.1V/Cell
LiIo
2.5V/Cell-4.0V/Cell
LiFe
2V/Cell-3.5V/Cell
LiHV
3V/Cell-4.25V/Cell
LTO
1.5V/Cell-2.9V/Cell
NiZn
0.9V/Cell-1.6V/Cell
User
0.5V/Cell-4.5V/Cell
End Current:
1%-100%; default: 50%
Regenerative Mode:
OFF (default), To input, To channel
- 19 -
4512DUO
3.85V/Cell
3.75V/Cell
3.30V/Cell
3.9V/Cell
2.5V/Cell
1.0V/Cell
default
3.5V/Cell
default
3.5V/Cell
default
2.5V/Cell
default
3.6V/Cell
default
1.8V/Cell
default
1.1V/Cell
default
1.0V/Cell