Nimh/Nicd Battery Setup; Nimh/Nicd Battery Charge Setup - iCharger 4512DUO User Manual

Dual balance charger/discharger/dc power
Table of Contents

Advertisement

NiMH/NiCd Battery Setup
After adding a program, it will switch to NiMH/NiCd battery in Type option on the MEMORY SETUP interface. Set the
Capacity, the number of cells for NiMH/NiCd battery cannot be set, and the charger sets Auto by default, after editing all
parameters for the program, click "Save" to save and return to the previous interface.
As shown in above picture, the program of NiMH, NiCd has the following modes: Charge, Discharge and Cycle.
NiMH/NiCd Battery Charge Setup
Select Program→Charge to enter CHARGE SETUP interface.
Charge Mode has Normal and Reflex modes available; use reflex mode to charge the battery, it can reduce the heat in
the battery; please see charging principle on Important Notes.
NiMH/NiCd Battery Charge Advanced Setup
Click "Advanced" to enter CHARGE OPTION SETUP interface.
For the over-discharged NiMH/NiCd battery, the voltage may be close to 0V, tick "Allow 0V Charging" to allow charge
with 0V.
Tick Trickle Enable→Enable to activate trickle charge and set the parameters.
Tick Enable to activate trickle charge. Trickle charge means when the standard charge is completed, the charger will
charge the battery with the setting trickle Current until the setting trickle Timeout, then to stop the charging process.
NiMH/NiCd Battery Charge Safety Setup
Click "Safety" to enter CHARGE SAFETY SETU interface,
See details about setting on LiPo/LiIo/LiFe/LiHV/LTO/NiZn/User Charge Safety Setup.
Dual Balance Charger/Discharger/DC Power
Capacity:
Ignore(default),50-999900mAh
Chg Current:
0.05A-45A; default: 2A
Chg Mode:
Normal (default), Reflex
Sensitivity:
1mV-20mV; default: 3mV(NiMH), 5mV(NiCd)
Delay time:
0Min-20Min; default: 3Min
Trickle current:
0.02A-1A; default: 0.05A
Trickle timeout:
1Min-999Min; default: 5Min
- 22 -