iCharger 4512DUO User Manual page 27

Dual balance charger/discharger/dc power
Table of Contents

Advertisement

1
3
4
The maximum power limit for regenerative discharge is equal to the maximum power limit for charge. When the input
or output power of charger is limited, it will trigger the CH-1/CH-2 Channel Partiality. When Partiality switches to
Same, charger assigns the output power equally to two channels, switch to CH-1 or CH-2, the charger will give priority
to the selected channel output, while the output power of other channel may be reduced to 50W (discharge for 5W).
Input Limit Setup
Select SYSTEM MENU→Input Limit to enter the setup interface.
1
After selecting input source, enter the relevant power supply setting to set the parameters, after setting click "Save" to save
and return to the previous interface.
1
2
3
4
5
6
7
8
After ticking Regenerative enable, if run the regenerative discharge to input, the electrical discharged will be re-charged
as the battery of input power.
When the input source unselected, pop up the MANAGE interface, as below:
Dual Balance Charger/Discharger/DC Power
1/2
CH-1/CH-2 Output Power Setup
.
2
Charge:
5W-2000W; default: 2000W
Discharge:
5W-130W; default: 130W
3
Partiality:
Same (default), CH-1, CH-2
.
4
Anti sparking of output port:
.
1
Four options of Input Sources
.
1.Low Voltage Limit:
2.Current Limit:
3.Charge Power Limit:
4.Regenerative enable
5.Regen. Voltage Limit:
6.Regen. Current Limit:
7.Regen. Power Limit:
8.Regen. Capacity Limit:
- 27 -
Maximum Power Limit for charge
Maximum Power Limit for discharge
10V-48V; default: 10V
1A-70A; default: 70A
5W-2200W; default: 2200W
10V-48V; default: 14.5V
1A-70A; default: 10A
5W-2200W; default: 2200W
Ignore (default),100-999900mAh
4512DUO

Advertisement

Table of Contents
loading

Table of Contents