"Storage" Charge/Discharge A Lithium Battery; Discharging A Lithium Battery - iCharger 1010B User Manual

Synchronous balance charger/discharger
Table of Contents

Advertisement

iCharger Synchronous Balance Charger/Discharger

"Storage" charge/discharge a Lithium battery

This mode is for charging/discharging a Lithium battery that is not to be used for an extended period. The
program determines whether to charge or discharge the battery based on the configured target voltage and
the measured initial voltage of the battery. The nominal target storage voltage depends on the type of Lithium
battery: 3.75V/cell for Lilo, 3.85V/cell for LiPo and 3.3V/cell for LiFe. If at the start the battery voltage exceeds
the target storage voltage the program will start to discharge rather than charge.
LiPo STORAGE
LiPo STORAGE
LiPo STORAGE
LiPo STORAGE
1.0A
1.0A
1.0A
1.0A
11.1V(3S)
11.1V(3S)
11.1V(3S)
11.1V(3S)
-
+
-
Dec
Inc
Dec
Batt type
Start/Enter
stop
>3 seconds
R:03SER S:03SER
R:03SER S:03SER
R:03SER S:03SER
R:03SER S:03SER
CONFIRM(ENTER)
CONFIRM(ENTER)
CONFIRM(ENTER)
CONFIRM(ENTER)
Batt type
Start/Enter
stop
Battery
V-BP
Charge
Series
Current
Li03 1.0A 12.60V
Li03 1.0A 12.60V
Li03 1.0A 12.60V
Li03 1.0A 12.60V
STO 00993 059
STO 00993 059
STO 00993 059
STO 00993 059: : : : 51 51 51 51
work
charged
charging
state
capacity
time
number
charge
of cells
current

Discharging a Lithium battery

In this mode, you can set the target per-cell voltage and hence the final voltage (final voltage=cell
voltage*number of cells). The lowest allowable cell voltage depends on the type of Lithium battery: 2.50V for
Lilo, 3.00V for LiPo and 2.00V for LiFe per cell. If the battery is connected to the balance port, the iCharger
can monitor the individual cell voltages. The discharge will stop immediately if any cell falls below the
configured final voltage.
LiPo DCHG 3.30V
LiPo DCHG 3.30V
LiPo DCHG 3.30V
LiPo DCHG 3.30V
1.0A
1.0A
11.1V(3S)
11.1V(3S)
1.0A
1.0A
11.1V(3S)
11.1V(3S)
-
+
-
Dec
Inc
Dec
Batt type
Start/Enter
stop
>3 seconds
R:03SER S:03SER
R:03SER S:03SER
R:03SER S:03SER
R:03SER S:03SER
CONFIRM(ENTER)
CONFIRM(ENTER)
CONFIRM(ENTER)
CONFIRM(ENTER)
Batt type
Start/Enter
stop
Battery
V-BP
Charge
Series
Current
Li03 1.0A 12.60V
Li03 1.0A 12.60V
Li03 1.0A 12.60V
Li03 1.0A 12.60V
DSC 00993 059: : : : 51 51 51 51
DSC 00993 059
DSC 00993 059
DSC 00993 059
work
discharge
discharging
state
capacity
time
number
discharge
of cells
current
Storage of Lithium battery. The left side of the first line shows the type of
battery you selected in the User setup (LiPo, Lilo or LiFe). The value on the
left side of second line sets the charge/discharge current and the value on
the right side of second line sets the cell count and voltage of the battery
+
pack. After setting the current and voltage, press Start/Enter for more than
Inc
3 seconds to start the next process.
Charge current: 0.05 – 10A, Voltage: 1 – 10 series (1 – 6 series for 106B)
The number of cells you set and the processor detects. The left side of the
first line 'R:xxSER' shows the number of cells detected by the iCharger and
the right side of the first line 'S:xxSER' is the number of cells set by the user.
If the numbers are different you should make sure that the configured
number and the actual number for the battery are the same and then you
can start charging by pressing Start/Enter. If not, press Batt type/Stop to
go back to the previous screen and adjust the setting.
Lithium STORAGE charging mode. The screen shows the status during the
charging process. You can stop charging at any time by pressing Batt
type/Stop. Press Inc
voltage information) and press
information.
battery
voltage
Discharge Lithium battery. The left side of the first line shows the type of
battery you selected in the User setup (LiPo, Lilo or LiFe) and the value on
the right side shows the final discharge voltage of each cell. The value on
the left side of second line sets the charge current and the value on the right
side of second line sets the cell count and voltage of the battery pack. After
+
setting the current and voltage, press Start/Enter for more than 3 seconds
Inc
to start the next process.
Per-cell final voltage:
Discharge current: 0.05 – 7A , Cell count: 1 – 10S (1 – 6S for 106B)
The number of cells you set and the processor detects. The left side of the
first line 'R:xxSER' shows the number of cells detected by the iCharger and
the right side of the first line 'S:xxSER' is the number of cells set by the user.
Usually, the auto-detect number won't lower than the number set by the
user. If the numbers are different you should make sure that the configured
number and the actual number for the battery are the same and then you
can start charging by pressing Start/Enter. If not, press Batt type/Stop to
go back to the previous screen and adjust the setting.
Discharge process. The iCharger allow its user to alter the discharging
current during the process. Press Start/Enter to make the discharge current
blink then press Inc
press Start/Enter to confirm the alteration. You can stop discharging at any
time by pressing Batt type/Stop. Press Inc
(see the balance voltage information) and press
battery
General Status information.
voltage
to display each cell's voltage (see the balance
Dec to display the General Status
LiPo (3.00 – 4.20V), Lilo(2.50 – 4.10V), LiFe(2.00 – 3.60V)
to increase or press
-12-
1010B/106B
Dec to decrease the value and
to display each cell's voltage
Dec to display the

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

106b

Table of Contents