Lipo/Liio/Life Battery Charge/Discharge Setup; Lipo/Liio/Life Battery Charge Setup - iCharger 308DUO User Manual

Synchronous balance charger/discharger
Table of Contents

Advertisement

Note: 1. Channel Mode has asynchronous, synchronous available, see more details on Page10
Dual-channel Connection
2. If select synchronous mode, the maximum charge/discharge current setting will change from
30A to 50A.
3. If tick Auto saves before the program runs, the parameters set on the Run program will be
saved automatically, and the Run Program will display "Auto save" ( shown in the following
left picture), otherwise it will display "Don't save!" (shown in the following right picture); for
the built-in program, the Auto save before the program runs option is ticked by default.
4. If tick Log save to SD card, the log files will be saved to SD card when running program, and
vice versa.
 LiPo/LiIo/LiFe Battery Charge/Discharge Setup
After adding a program, it will switch to LiPo/LiIo/LiFe battery in Type option on the MEMORY SETUP interface, and
set the number of cells and capacity, if there is no setting for the number of cells, the charger will set Auto by default.
After editing all parameters for the program, click "
As shown in the above picture, the program of LiPo, LiIo, LiFe battery has: Charge, Storage, Discharge, Cycle and
Balance Only.

LiPo/LiIo/LiFe Battery Charge Setup

Select Program→Charge to enter Charge setup interface.
Notes.
" to save and return to the previous interface.
Cells: Auto(default), 1-8S
Chg Current:
Chg Mode:
Chg End Current:
Chg Cell Volt:
- 16 -
Synchronous Balance Charger/Discharger
0.05A-30A; default: 2A
Slow Balance, Normal Balance( default),
Fast Balance, User Balance, Not Balance
1%-50%; default: 10%
3.85V/Cell-4.35V/Cell;
Default: 4.2V/Cell
308DUO V1.1.0