Beko DRYPOINT RA III 1080 Translation Of Original Installation And Operation Manual page 82

Compressed air refrigeration dryer
Table of Contents

Advertisement

Original installa�on and opera�on manual
Advanced parameters, protected by security PIN
Code
Description / explanation
Reset by Password
Clearing of WARNINGS / ALARMS
RbP
NO = clearing allowed locally (by User
(*2)
Interface) and remotely
YES = clearing allowed only locally (by User
Interface)
Number of Alarms
NoA
Maximum number of local clearings
(*3)
allowed within the time frame defined in
TtPR
Time to Possible Reset
TtPR
Time frame within which the maximum
(*3)
number of local clearings defined in NoA
(*4)
can be performed
Programmed Service Protected Reset
Enables / disables the security PIN to clear
the Warning W6
PSPR
NO = clearing of Warning allowed without
typing the security PIN
YES = clearing of Warning allowed only
after typing the security PIN
(*2) With RbP = NO, the maximum number of remote clearings allowed within 60 minutes is 3.
(*3) Effective only with RbP = YES.
(*4) With TtPR = 0, when NoA setting is reached, the device asks the typing of the security PIN to clear a
WARNING / ALARM.
82 | 120
Value
Accuracy
range
NO, YES
-
1 ... 10
1
0 ... 24 hours
1
NO, YES
-
DRYPOINT
®
RA III
Default
value
NO
1
1
NO

Advertisement

Table of Contents
loading

Table of Contents