Beko DRYPOINT RA III 1080 Translation Of Original Installation And Operation Manual page 107

Compressed air refrigeration dryer
Table of Contents

Advertisement

DRYPOINT
®
RA III
WARNING code – Text
W1 – Low Dew Point
Trigger: T1 < -1,0 °C
Reset: T1 ≥ 0,0 °C
Delay: 3 minutes
W2 – High Dew Point
Trigger: T1 > had value
ResehadHdA value - 1 K
Delay: Hdd value
W3 – Probe Fault T2
Trigger: BT2 fault
Reset: BT2 reset
Delay: none
W4 – Probe Fault T3
Trigger: BT3 fault
Reset: BT3 reset
Delay: none
W5 – Drainer
Trigger: DI5 open
Reset: DI5 closed
Delay: 20 minutes
W5 Dn nn
Drainer, specific faults
W6 – Programmed Service
Trigger: SrV value
Reset: timer reset
Delay: none
W7 – High Discharge Temp.
Trigger: T4 > 100,0 °C
Reset: T4 < 95,0 °C
Delay: 60 seconds
Cause
Probe BT1, the dew point
temperature is too low.
The value of parameter HdA is
too low.
Probe BT1, the dew point
temperature is too high.
The electrical wiring between
Probe BT2 and Electronic Control
Unit is interrupted.
Probe BT2, defective or faulty.
The electrical wiring between
Probe BT3 and Electronic Control
Unit is interrupted.
Probe BT3, defective or faulty.
The condensate drain is defective
or faulty
The electrical wiring between
condensate drain and Electronic
Control Unit is interrupted.
Compressed air line is
depressurised.
Condensate drain specific
malfunction.
The maintenance time is expired.
Probe BT4, the temperature on
discharge side of refrigerant
compressor is too high.
Original installa�on and opera�on manual
Action
Refer to section "16.2 Specific
malfunctions" on page 114,
"Probe BT1, dew point
temperature too low".
Increase the value of parameter
HdA.
Refer to section "16.2 Specific
malfunctions" on page 114,
"Probe BT1, dew point
temperature too high".
Restore the electrical wiring.
Replace the probe.
Restore the electrical wiring.
Replace the probe.
Consult the BEKOMAT
Installation and operation
manual.
Restore the electrical wiring.
Pressurise the compressed air
line.
Consult BEKO TECHNOLOGIES
Refer to section "10.2
Maintenance work" on page 87.
Refer to section "16.2 Specific
malfunctions" on page 114,
"Probe BT4, compressor
discharge temperature too high".
®
107 | 120