Beko DRYPOINT RA III 1080 Translation Of Original Installation And Operation Manual page 66

Compressed air refrigeration dryer
Table of Contents

Advertisement

Original installa�on and opera�on manual
66 | 120
Description / explanation
Process values history screen
Graphical and numerical representation of actual
process values for the last 60 minutes of device
operation.
Stored values shifted out the last 60 minutes are
definitively lost.
1. Use buttons T1 [16], T2 [17], T3 [18],
2. Touch the graph to position the graph
3. Use the CURSOR L and CURSOR R
4. Press the BACK button [27] to return
Data recording screen
To record the process values of a certain time
frame, a USB memory stick must be already
installed by the maintenance personnel. Refer to
section "7.2.7 USB memory stick for data log
storage " on page 55.
1. Set the recording time with the
2. Start the recording pressing the
T4 [19], T5 [20], HP [21], LP [22],
EHGBV [23], FAN [24] to show / hide on
the graph the corresponding traces.
cursor roughly near the required time.
buttons [25, 26] to fine tune the position
of the graph cursor on the required time.
Positioning accuracy is +/- 15 seconds.
back to previous screen.
CURSOR UP and CURSOR DOWN
buttons [28, 29]. The picture shows a
setting of recording time for 2 hours and
30 minutes with a data sampling every
60 seconds.
CONFIRM button [31] or abort the
command pressing EXIT button [30].