Salda RIRS EKO 3.0 400 VEL Mounting And Installation Instruction
Hide thumbs Also See for RIRS EKO 3.0 400 VEL:

Advertisement

Quick Links

RIRS 400-700 V EKO 3.0
EN
MOUNTING AND INSTALLATION INSTRUCTION

Advertisement

Table of Contents
loading

Summary of Contents for Salda RIRS EKO 3.0 400 VEL

  • Page 1 RIRS 400-700 V EKO 3.0 MOUNTING AND INSTALLATION INSTRUCTION...
  • Page 2: Table Of Contents

    1. CONTENTS 1. CONTENTS 2. SYMBOLS AND MARKING 3. SAFETY INSTRUCTIONS AND PRECAUTIONS 4. INFORMATION ABOUT THE PRODUCT 4.1. DESCRIPTION 4.2. DIMENSIONS AND WEIGHT 4.3. TECHNICAL DATA 4.4. OPERATING CONDITIONS 4.5. STANDARD PACKAGE OF COMPONENTS 4.6. DESCRIPTION OF COMPONENTS 5. INSTALLATION 5.1.
  • Page 3: Symbols And Marking

    2. SYMBOLS AND MARKING Warning – pay attention Additional information Apply the technical label on the unit (in an easily accessible location) or on the dashed location of the technical manual to keep the important information about the unit. Figure 2.1 Technical label 1 - Logo;...
  • Page 4: Safety Instructions And Precautions

    3. SAFETY INSTRUCTIONS AND PRECAUTIONS Read these instructions very carefully before installing and using this equipment. Installation, connection and maintenance should be carried out Main safety rules Danger • parts of the device have stopped. • Make sure that the fans are not accessible through air ducts or branch openings. •...
  • Page 5: Information About The Product

    4. INFORMATION ABOUT THE PRODUCT 4.1. DESCRIPTION Not suitable for operation in pools, saunas and other similar premises. 4.2. DIMENSIONS AND WEIGHT RIRS 400-700 V EKO 3.0 v2023.1 EN |...
  • Page 6: Technical Data

    RIRS EKO 3.0 400 VEL 400 VER 400 VWL 400 VWR 700 VEL 700 VER 700 VWL 700 VWR [mm] 1100 [mm] [mm] ØD [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] WEIGHT [kg]...
  • Page 7: Operating Conditions

    4.4. OPERATING CONDITIONS RIRS EKO 3.0 400 VE 400VW 700VE 700VW Minimum outdoor air temperature Maximum outdoor air temperature Minimum extracted air temperature Maximum extracted air temperature Maximum extracted air relative humidity Minimum ambient air temperature Maximum ambient air temperature Installation indoor indoor...
  • Page 8: Installation

    5. INSTALLATION 5.1. RECEPTION OF GOODS Each device is carefully checked before transportation. When receiving the goods, checking the devices for any damage made during transporta- tion is recommended. If any damage to the unit is observed, immediately contact the representatives of a transport company. Please inform the representative of the manufacturer, if any deviation of the device is noticed.
  • Page 9: Piping And Instrumentation Diagram

    • • • • Installation • Before commencing the installation of the unit, please check if all ordered equipment been delivered. Any deviation from the ordered equip- ment list must be reported to the product supplier. 5.4. PIPING AND INSTRUMENTATION DIAGRAM Figure 5.4.1 * KE1 - only in electrical version;...
  • Page 10: Mounting

    THE LIST OF COMPONENTS Supply air fan Exhaust fan Exhaust air temperature sensor Supply air temperature sensor Extract air temperature and humidity sensor sensor Computer Electric heater* Outdoor air damper actuator Exhaust air damper actuator Outdoor air temperature sensor Ventilated premises MB-Gateway Rotor heat exchanger DX cooler...
  • Page 11: Unit Placing And Mounting Positioning Requirements

    5.5.1. UNIT PLACING AND MOUNTING POSITIONING REQUIREMENTS 1,5xL Figure 5.5.1.1 5.5.2. FLOOR MOUNTING • The installation should be performed having positioned the units in horizontal direction only. • Install the supporting legs. • The units are assembled from separate sections. •...
  • Page 12: Start-Up Recommendations

    5.8. START-UP RECOMMENDATIONS 5.8.1. SYSTEM PROTECTION RIRS EKO 3.0 400 VE 400 VW 700 VE 700 VW F1 (Q1) 10 A 16 A 6,3 A 10 A RIRS EKO 3.0 400 VE 400 VW 700 VE 700 VW Mains Fuse 10 A 16 A 5.8.2.
  • Page 13: Maintenance

    6. MAINTENANCE 6.1. SAFETY INSTRUCTION Unplug the unit from the mains before opening the door (disconnect the power plug from the outlet or in case a two-pole automatic circuit breaker is installed, disconnect it as well. Make sure that it cannot be turned on by the third parties) and wait until the fans completely stop (for about 2 min.).
  • Page 14: Filters Maintenance

    6.4. FILTERS MAINTENANCE manual or on our website www.salda.lt 6.5. ROTOR MAINTENANCE • Maintenance of rotor heat exchanger must be performed on annual basis, once per year. • exchanger are tight. • clamp of the rotor heat exchanger section, and then remove the heat exchanger.
  • Page 15: Heater Maintenance

    • Do not plunge the motor place. • Make sure the impeller is free of any obstacles. • • In case the fan does not automatically start up or stop after maintenance, contact the manufacturer. panel. Prior to commencing any maintenance or repair works, make sure the unit is disconnected from the power source. 6.7.
  • Page 16: Control

    Stouch Modbus RTU (RS485) MB-GATEWAY + WIFI router SALDA AIR mobile application ST-SA-Control BMS over Modbus TCP/IP FLEX BMS over BACnet TCP/IP 7.2. DEVICE FUNCTIONS WEB application and SALDA AIR mobile application. | EN RIRS 400-700 V EKO 3.0 v2023.1...
  • Page 17: Connection Of Accessories

    8. CONNECTION OF ACCESSORIES 8.1. FIRE PROTECTION SIGNAL INPUT (FIRE PROTECTION INPUT (NC)) 8.2. EXTERNAL CO /PRESSURE SENSORS /PRESSURE (input 0-10 VDC) sensors Sensors connection: detection. The CO transmitter is installed in the extract air duct or room. 8.3. ROOM CO TRANSMITTER INSTALLATION RECOMMENDATION 5 0 c m i n .
  • Page 18: Connection Of Supply And Extract Air Dampers

    8.4. CONCENTRATION ACCORDING TO PETTENKOFER LIMIT 8.5. CONNECTION OF SUPPLY AND EXTRACT AIR DAMPERS tuators. Wiring diagram for RIRS VE EKO 3.0 M2, M3 – Open/Close damper actuators. Upon activation of outputs X16:17, X16:20 the dampers shall open. Upon activation of outputs X16:16, X16:19 the dampers shall close.
  • Page 19: Connection Of Remote Control Panel Or Modbus

    8.6. CONNECTION OF REMOTE CONTROL PANEL OR MODBUS 8.7. WATER HEATER CIRCULATION PUMP AND VALVE ACTUATOR EKO 3.0 units). Wiring diagram RIRS 400-700 V EKO 3.0 v2023.1 EN |...
  • Page 20: Recommended Scheme For Connection Of Internal And External Components

    8.8. RECOMMENDED SCHEME FOR CONNECTION OF INTERNAL AND EXTERNAL COMPONENTS | EN RIRS 400-700 V EKO 3.0 v2023.1...
  • Page 21 RIRS 400-700 V EKO 3.0 v2023.1 EN |...
  • Page 22: Possible Faults And Troubleshooting

    9. POSSIBLE FAULTS AND TROUBLESHOOTING FAILURE CAUSE EXPLANATION/CORRECTIVE ACTIONS No supply voltage Unit is not operating leakage relay is active (if installed by the installer) protection Check if the fans are rotating. Air supply heater or pre-heater is not operat- Possible heater or unit failure.
  • Page 23: Ecodesign Data Table

    10. ECODESIGN DATA TABLE MODEL RIRS 400 VE/VW EKO 3.0 consumption SEC Class Climate Control Control typology (SEC) zone factor [ kWh/m²a ] [ kWh/a ] [ kWh/a ] 0,85 -35,7 4224 Average 0,65 -41,8 4488 0,85 -76,1 8262 Cold 0,65 -84,7 8780...
  • Page 24: Declaration Of Conformity

    11. DECLARATION OF CONFORMITY Manufacturer SALDA, UAB LT-78109 Šiauliai, Lithuania Tel.: +370 41 540415 www.salda.lt RIRS * EKO 3.0 Machinery Directive 2006/42/EC EMC Directive 2014/30/EU Low Voltage Directive 2014/35/EU Ecodesign Directive 2009/125/EC RoHS 2 Directive 2011/65/EU Ecodesign requirements for ventilation units Nr. 1253/2014 Energy labelling of residential units Nr.
  • Page 25: Warranty

    The manufacturer reserves the right to change this technical passport at any time without prior notice if some typographic errors or inaccurate information is found, as well as after improving the apps and/or the devices. Such changes will be original device. The newest manual version is available at https://select.salda.lt 12.1. LIMITED WARRANTY COUPON 24 months* ..................................
  • Page 26 RIRS 400-700 V EKO 3.0 v2023.1...
  • Page 27 RIRS 400-700 V EKO 3.0 v2023.1...
  • Page 28 Look at the product label. ** - At least. NOTE. The customer shall be required to complete the Product Maintenance Table. MANUALS IN OTHER LANGUAGES https://select.salda.lt/file/ https://select.salda.lt/file/ https://select.salda.lt/file/ https://select.salda.lt/file/ https://select.salda.lt/file/ rirs https://select.salda.lt/file/ https://select.salda.lt/file/ https://select.salda.lt/file/ rirs MAN000312 Ragainės g. 100 +370 41 540 415 Šiauliai LT-78109, LITHUANIA...