  • Page 1 RIRS 400700 V EKO 3.0 MOUNTING AND INSTALLATION INSTRUCTION...
  • Page 2: Table Of Contents

    1. CONTENT 2. SYMBOLS AND MARKING 3. SAFETY INSTRUCTIONS AND PRECAUTIONS 4. INFORMATION ABOUT THE PRODUCT 4.1. DESCRIPTION 4.2. DIMENSIONS AND WEIGHT 4.3. TECHNICAL DATA 4.4. OPERATING CONDITIONS 4.5. STANDART PACKAGE OF COMPONENTS 4.6. DESCRIPTION OF COMPONENTS 5. INSTALATION 5.1. RECEPTION OF GOODS 5.2.
  • Page 3: Symbols And Marking

    2. SYMBOLS AND MARKING Warning – pay attention Additional information Apply the auxiliary label on the unit (on an easily accessible location) or on the dashed location of the technical manual in order to keep the important information about the unit. Figure.
  • Page 4: Safety Instructions And Precautions

    3. SAFETY INSTRUCTIONS AND PRECAUTIONS Read these instructions very carefully before installing and using this equipment. Installation, connection and maintenance should be carried out Main safety rules Danger • of the device have stopped. • Make sure that the fans are not accessible through air ducts or branch openings. •...
  • Page 5: Information About The Product

    4. INFORMATION ABOUT THE PRODUCT 4.1. DESCRIPTION Not suitable for operation in pools, saunas and other similar premises. 4.2. DIMENSIONS AND WEIGHT RIRS 400-700 V EKO 3.0 v2020.1 EN |...
  • Page 6: Technical Data

    RIRS EKO 3.0 400 VEL 400 VER 400 VWL 400 VWR 700 VEL 700 VER 700 VWL 700 VWR [mm] 1100 1100 1100 1100 [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]...
  • Page 7: Operating Conditions

    4.4. OPERATING CONDITIONS RIRS EKO 3.0 400 VE 400VW 700VE 700VW Minimum outdoor air temperature Maximum outdoor air temperature Minimum extracted air temperature Maximum extracted air temperature Maximum extracted air relative humidity Minimum ambient air temperature Maximum ambient air temperature Installation indoor indoor...
  • Page 8: Instalation

    5. INSTALATION 5.1. RECEPTION OF GOODS Each device is carefully checked before transportation. When receiving the goods, checking the devices for any damage made during transportation is recommended. If any damage to the unit is observed, immediately contact the representatives of a transport company. Please inform the representative of the manufacturer, if any deviation of the device is noticed.
  • Page 9: Piping And Instrumentation Diagram

    • • • • • Before commencing the installation of the unit, please check if all ordered equipment have been delivered. Any variation from the ordered equipment list must be reported to the product supplier. 5.4. PIPING AND INSTRUMENTATION DIAGRAM * KE1 - only in electrical version;...
  • Page 10: Mounting

    THE LIST OF COMPONENTS Supply air fan Exhaust fan Exhaust air temperature sensor Supply air temperature sensor Extract air temperature and humidity sensor CO2 sensor Computer Electric heater* Outdoor air damper actuator Exhaust air damper actuator Outdoor air temperature sensor Ventilated premises MB-Gateway Rotor heat exchanger...
  • Page 11: Unit Placing And Mounting Positioning Requirements

    5.5.1. UNIT PLACING AND MOUNTING POSITIONING REQUIREMENTS 1,5xL 5.5.2. FLOOR MOUNTING • The installation should be performed having positioned the units in horizontal direction only. • Install the supporting legs. • The units are assembled from separate sections. • • 5.6.
  • Page 12: Start-Up Recommendations

    5.8. START-UP RECOMMENDATIONS 5.8.1. SYSTEM PROTECTION RIRS EKO 3.0 400 VE 400 VW 700 VE 700 VW F1 (Q1) 10 A 16 A 6,3 A 10 A RIRS EKO 3.0 400 VE 400 VW 700 VE 700 VW Mains Fuse 10 A 16 A 5.8.2.
  • Page 13: Maintenance

    6. MAINTENANCE 6.1. SAFETY INSTRUCTION Unplug the unit from the mains before opening the door (disconnect the power plug from the outlet or in case a two-pole automatic circuit breaker installed, disconnect it as well. Make sure that it cannot be turned on by third parties) and wait until the fans completely stop (for about 2 min.).
  • Page 14: Filters

    6.4. FILTERS direction. manual or on our website www.salda.lt 6.5. ROTOR MAINTENANCE • Maintenance of rotor heat exchanger must be performed on annual basis, once per year. • exchanger are tight. • clamp of the rotor heat exchanger section, and then remove the heat exchanger.
  • Page 15: Heater Maintenance

    • • Make sure the impeller is free of any obstacles. • • Prior to commencing any maintenance or repairs , make sure the ventilation units is disconnected from the power source. 6.7. HEATER MAINTENANCE • • • • • If necessary, electric heater can be removed. Disconnect the electrical connector from the heater and remove the heater. 6.8.
  • Page 16: Control

    BMS over Modbus TCP/IP FLEX BMS over BACnet TCP/IP 7.2. DEVICE FUNCTIONS WEB application and SALDA AIR mobile application. Refer to the instruction manual of the existing control device for unit control instructions. | EN RIRS 400-700 V EKO 3.0 v2020.1...
  • Page 17: Accessories

    8. ACCESSORIES RIRS EKO 3.0 400 VE 400 VW 700 VE 700 WV ABV 250 ACC000056 ACC000056 WSG 160 FIT000403 FIT000403 Outlet covers ALU 160 FIT000127 FIT000127 ALU 250 FIT000129 FIT000129 VVP45.10-0.63 ACC000140 ACC000140 ACC000140 ACC000140 Valves VXP45.10-0.63 ACC000143 ACC000143 ACC000143 ACC000143 AVA 160...
  • Page 18: Connection Of Accessories

    ACC000305 ACC000305 ACC000305 ACC000305 ACC000316 ACC000316 Actuators ACC000317 ACC000317 ACC000318 ACC000318 ACC000318 ACC000318 SKG-A 160 FIT000203 FIT000203 Dampers SKG-A 250 FIT000205 FIT000205 MUTE 160X600 FIT000289 FIT000289 MUTE 160X900 FIT000290 FIT000290 Silencers MUTE 250X600 FIT000293 FIT000293 MUTE 250X900 FIT000294 FIT000294 Filter set RIRS 400 V/H EKO 3.0 ACC005258 ACC005258 (ePM10-50+ePM1-70-2pcs.)
  • Page 19: Co2 Concentration According To Pettenkofer Limit

    8.1.3. ROOM CO2 TRANSMITTER INSTALLATION RECOMMENDATION 5 0 c m i n . min. 60 cm max. 400m If the duct CO2 transmitter is used, it must be installed in the extract air duct. To install duct transmitters, hole drilling tools are required .
  • Page 20: Connection Of Remote Control Panel Or Modbus

    is deactivated, the supply air damper closes. 8.1.6. CONNECTION OF REMOTE CONTROL PANEL OR MODBUS 8.1.7. WATER HEATER CIRCULATION PUMP AND VALVE ACTUATOR EKO 3.0 units). Wiring diagram | EN RIRS 400-700 V EKO 3.0 v2020.1...
  • Page 21: Recommended Scheme For Connection Of Internal And External Components

    8.1.8. RECOMMENDED SCHEME FOR CONNECTION OF INTERNAL AND EXTERNAL COMPONENTS Figure 8.1.8.1. RIRS 400-700 V EKO 3.0 v2020.1 EN |...
  • Page 22 Figure 8.1.8.2. | EN RIRS 400-700 V EKO 3.0 v2020.1...
  • Page 23: Possible Faults And Troubleshooting

    9. POSSIBLE FAULTS AND TROUBLESHOOTING FAILURE CAUSE EXPLANATION / CORRECTIVE ACTIONS No supply voltage Unit is not operating relay is active (if installed by the installer) ic protection fans are rotating Air supply heater or pre-heater is not operat- Possible heater or unit failure. MUST contact ing or malfunctioning (if installed) Manual protection is activated elimination.
  • Page 24: Ecodesign Data Table

    10. ECODESIGN DATA TABLE MODEL RIRS 400 VE/VW EKO 3.0 consumption SEC Class Climate Control Control typology (SEC) zone factor [ kWh/m²/a ] [ kWh/a ] [ kWh/a ] 0,85 -35,7 4224 Average 0,65 -40,0 4383 0,85 -76,1 8262 Cold 0,65 -81,9 8574...
  • Page 25: Declaration Of Confimity

    11. DECLARATION OF CONFIMITY Manufacturer SALDA, UAB LT-78109 Šiauliai, Lithuania Tel.: +370 41 540415 www.salda.lt RIRS * EKO 3.0 Machinery Directive 2006/42/EC EMC Directive 2014/30/EU Low Voltage Directive 2014/35/EU Ecodesign Directive 2009/125/EC RoHS 2 Directive 2011/65/EU Ecodesign requirements for ventilation units Nr. 1253/2014 Energy labeling of residential units Nr.
  • Page 26: Warranty

    12. WARRANTY date. such damage. damaged by installing the control system. 4.1. mechanical damage; 4.2. damage caused by entering outside objects, materials, liquids; lation and mounting regulations, deliberate or careless users or third-party behavior. days and deliver the equipment to manufacturer. Delivery costs should be covered by customer. Manufacturer reserves the right to change this technical passport any time without prior notice, if some typographic errors or inaccurate information is found, as well as after improving the apps and/or the devices.
  • Page 27 RIRS 400-700 V EKO 3.0 v2020.1...
  • Page 28 Look at the product label. ** - At least. NOTE. The customer shall be required to complete the Product Maintenance Table. MANUALS IN OTHER LANGUAGES https://select.salda.lt/file/ https://select.salda.lt/file/ https://select.salda.lt/file/ https://select.salda.lt/file/ https://select.salda.lt/file/ https://select.salda.lt/file/ MAN000312 Ragainės g. 100 +370 41 540 415 Šiauliai LT-78109, LITHUANIA...