Description
Not used
Setting a value other than zero and one is not accepted if
already present in another input.
0: Not used
1: ImgBus
2: TA zone 1
3: TA zone 2
4: Safety thermostat (low temperature)
0: OFF/Storage tank probe
1: DHW inlet probe
2: Not available
Set the value in months at scheduled maintenance. When
the months set on the boiler display have expired, the icon (
) appears while error 97 is displayed on the remote
control CAR
. Boiler operation is still guaranteed. To reset
V2
the warning, set parameter P.16 at '0'; then you may set a new
month interval for the next scheduled maintenance.
Set the dialogue protocol available on terminals 44-41
0 : IMG BUS/DIM BUS. Select this mode when connecting
an Immergas remote control (e.g.: CAR
terminals 44/41
1 : Select this mode when a commercial remote control is
connected to terminals 44-41 (with this selection, the
control of the domestic hot water adjustments and max set
central heating flow remains available on the boiler panel)
Range
-
0-4
0-2
0-36
or a DIM) to
V2
0-1
Value
Default
customized
-
1
The value is
automatically
selected
depending on
the value set
in parameter
A.0
0
0