List of P family parameters.
To enter in the parameters of the family P, press "MODE" with P on the display. "P." will appear.
Press "INFO" to scroll the submenus of the P family.
Id
Parameter
Parameter
P.0
DHW max
P.1
Min C.H.
Central heating
P.2
max
Pump function-
P.3
ing
On-board relays
P.4
(5-6)
Relay 1 on relay
P.5
board (Option-
al)
Relay 2 on relay
P.6
board (Option-
al)
Relay 3 on relay
P.7
board (Option-
al)
For parameters P.4, P.5, P.6 and P.7, with the relay already set with a value other than zero, the others do not accept the same configuration.
102
Description
Defines the maximum heat output percentage of the boiler
during the D.H.W. phase compared to the maximum heat
output available
Defines the minimum output percentage of the boiler in cen-
tral heating mode
Defines the maximum output percentage of the boiler in
central heating mode
The circulator can be operated in two modes.
0: intermittent: in winter "mode" the circulator is controlled
by the room thermostat or remote control.
1: continuous: in "winter" mode the circulator is always
energised and therefore always running
0: OFF
1: Zone 1
2 control: Zone 2
3 control: Alarm
4: Not used
5: Not used
6: CH mode active
7: Not used
8: External system 3-way valve
9: Boiler pump
10: Remote activation Chiller
11: Not used
12: Not used
0: OFF
1: Zone 1
2 control: Zone 2
3 control: Alarm
4: Not used
5: Not used
6: CH mode active
7: External gas valve
8: External system 3-way valve
9: Boiler pump
10: Remote activation Chiller
11: Not used
See notes P.5
See notes P.5
Range
Default
VM 28: 100
0-100
VM 32: 96
VM 35: 100
0-100
0
VM 28: 80
0-100
VM 32: 78
VM 35: 96
0-1
0
0-12
0
0-11
0
0-11
0
0-11
0
Value
customized