List of G family parameters.
To enter in the parameters of the family G, press "MODE" with G on the display. "G." will appear. Press "INFO" to scroll the submenus of the G family.
Victrix Maior 28
Id
Parameter
Parameter
G.
Gas type
n.
Boiler model
Minimum no. of
S.0
fan revs
Maximum no. of
S.1
fan revs
Ignition phase no.
S.2
of fan revs
F.0
Flue length
Presence of clapet
F.1
valve on flue gas
(C
- C
)
(10)
(12)
* : 0 cannot be used; from 4 to 20 cannot be used; only 1-2-3 available.
Victrix Maior 32
Id
Parameter
Parameter
G.
Gas type
n.
Boiler model
Minimum no. of
S.0
fan revs
Maximum no. of
S.1
fan revs
Ignition phase no.
S.2
of fan revs
F.0
Flue length
Presence of clapet
F.1
valve on flue gas
(C
- C
)
(10)
(12)
* : 0 cannot be used; from 4 to 20 cannot be used; only 1-2-3 available.
Victrix Maior 35
Id
Parameter
Parameter
G.
Gas type
n.
Boiler model
Minimum no. of
S.0
fan revs
Maximum no. of
S.1
fan revs
Ignition phase no.
S.2
of fan revs
F.0
Flue length
Presence of clapet
F.1
valve on flue gas
(C
- C
)
(10)
(12)
* : 0 cannot be used; from 4 to 20 cannot be used; only 1-2-3 available.
If parameters are changed, the anomalies "E62" or "E72" will appear and automatic calibration will be required.
Description
Display gas type: nG (Methane) or LG (LPG)
Define the boiler model
Defines the operating speed of the fan at minimum output
Defines the operating speed of the fan at maximum output
Defines the operating speed of the fan during the ignition
phase
Defines the length of the flue (Parag. 3.12)
If present, automatic corrections are made to the fan's
operating range
Description
Display gas type: nG (Methane) or LG (LPG)
Define the boiler model
Defines the operating speed of the fan at minimum DHW
output
Defines the operating speed of the fan at maximum DHW
output
Defines the operating speed of the fan during the ignition
phase
Defines the length of the flue (Parag. 3.12)
If present, automatic corrections are made to the fan's
operating range
Description
Display gas type: nG (Methane) or LG (LPG)
Define the boiler model
Defines the operating speed of the fan at minimum DHW
output
Defines the operating speed of the fan at maximum DHW
output
Defines the operating speed of the fan during the ignition
phase
Defines the length of the flue (Parag. 3.12)
If present, automatic corrections are made to the fan's
operating range
Range
Default
nG-LG-AP
nG
0-20*
2
700-3000
2200
2000-8300
6350
2000-4500
3800
0-2
0
0-1
0
Range
Default
nG-LG-AP
nG
0-20*
1
700-3000
2200
2000-8300
6950
2000-4500
3800
0-2
0
0-1
0
Range
Default
nG-LG-AP
nG
0-20*
1
700-3000
2200
2000-8300
7200
2000-4500
3800
0-2
0
0-1
0
Customised
value
Customised
value
Customised
value
101