Id
Parameter
Parameter
Stand-by/OFF
P.8
configuration
External probe
P.9
reading
correction
Max power
correction for
P.10
flow rate
regulator
Configuration
P.11
Input 1 (40-41)
Configuration
P.12
Input 2 (14-15)
(*) : when connecting a DIM or zones control unit to terminals 21, 40 and 41, parameterP.11 must be set at 2.
Description
0: Antifreeze and anti-block active
1: Antifreeze off and anti-block active
2: Antifreeze anti-block off
3: Not used
If the reading of the external probe is not correct it is possible
to correct it in order to compensate any environmental
factors
If necessary, you can increase or decrease the boiler power
value with which the domestic hot water flow rate regulator
is set when operating in automatic mode.
The flow rate increases with positive values and decreases
with negative values.
Setting a value other than zero is not accepted if the function
is already present in another input (*).
0: OFF
1: zone 1 room thermostat generates central heating request
together with remote control (logic in AND)
2: room thermostat zone 1 generates a heating central
heating request as an alternative to the remote control (Logic
in OR)
3: room thermostat zone 2 generates a heating central
heating request as an alternative to the remote control (Logic
in OR)
4: Safety thermostat (low temperature)
See notes P.11
Range
Default
0-3
0
-9..9 °C
0
VM 28: 9
-9..9 KW
VM 32: 9
VM 35: 11
0-4
1
0-4
4
Value
customized
103