  • Page 1 MAGIS VICTRIX Instruction and recommendation booklet...
  • Page 3 Read the following pages carefully: you will be able to draw useful suggestions regarding the correct use of the appliance, the respect of which, will confirm your satisfaction for the Immergas product.
  • Page 4: Table Of Contents

    3.5 Converting the boiler to other types 1.7 Electric connection........9 2.7 Parameters and information menu..27 of gas............32 1.8 Immergas flue systems......10 2.8 Boiler shutdown ........28 3.6 Calibration of number of fan revs..32 1.9 Tables of resistance factors and 2.9 Restore central heating system pressure.
  • Page 5: Boiler Installation

    Assistance centre, which has specifically RECOMMENDATIONS. trained staff and original spare parts). Do not The Magis Victrix ErP boiler has been designed attempt to modify or repair the appliance alone. uniquely for wall-installation, for the produc- Failure to comply with the above implies personal tion of domestic hot water for household use responsibility and invalidates the warranty.
  • Page 6: Main Dimensions

    The materials used for the central heating circuit must be insulated. of Immergas boilers withstand ethylene and propylene glycol based antifreeze liquids (if the mixtures are prepared perfectly). For life and possible disposal, follow the sup-...
  • Page 7: Boiler Connection Unit

    1.4 BOILER CONNECTION UNIT. The connection unit comes as standard with the boiler. The kit includes: N°2 - adjustable expansion bolts N°2 - boiler support hooks N° 1 - Gas connection pipe Ø 18 (G) N° 2 - Domestic water pipe 1/2” (AF - AC) N°...
  • Page 8: Gas Connection

    Ensure correct gas cock connection. The gas sup- Attention: Immergas declines all liability in the ply pipe must be suitably dimensioned according event of damage caused by the inclusion of auto- to current regulations in order to guarantee cor- matic filling that is not its own brand.
  • Page 9: Electric Connection

    • Heat pump electrical connection. The boiler ers, multiple sockets or extension leads. can be combined with an Immergas heat pump • Comando Amico Remoto remote control which must be connected to the boiler as shown...
  • Page 10: Immergas Flue Systems

    Attention: the boiler must be installed ex- element in order to ensure sealing efficiency of clusively with an original Immergas “Green the coupling. Range” inspectionable air intake device and Attention: if the exhaust terminal and/or...
  • Page 11 Resistance Equivalent length Equivalent Equivalent length Equivalent length TYPE OF DUCT Factor in m of concentric length in metres in metres of pipe in m of concentric pipe Ø 60/100 of pipe Ø 80 Ø 60 pipe Ø 80/125 Intake m 7.3 Concentric pipe Ø...
  • Page 12: Outdoor Installation In Partially

    (B ) or tees additional protection for the boiler. It is via an Immergas ducting system (B recommended but not compulsory. The technical regulations in force must be respected.
  • Page 13: Concentric Horizontal Kit Installation

    Make sure that the external silicone wall concentric bend leaving the boiler. If addi- Immergas also provides a Ø 60/100 simplified sealing plate is properly inserted in the wall. tional components are assembled, the length...
  • Page 14: Concentric Vertical Kit Installation

    1.12 CONCENTRIC VERTICAL KIT male side (5) (smooth) into the flange (2) up to Position the fixed half-shell (5) on the aluminium INSTALLATION. the end stop; making sure that the wall sealing tile and insert the intake-exhaust pipe (7). Fit the Type C configuration, sealed chamber and plate has been fitted (3), this will ensure sealing Ø...
  • Page 15: Separator Kit Installation

    1.13 SEPARATOR KIT INSTALLATION. internal wall sealing plate has been fitted, this Type C configuration, sealed chamber and will ensure sealing and joining of the elements fan assisted. making up the kit. • Installation clearances (Fig. 1-19). The mini- Separator kit Ø 80/80. This kit allows air to come mum installation clearance measurements of in from outside the building and the fumes to exit the Ø...
  • Page 16: Adaptor C9 Kit Installation

    - Mount the cover (A) complete with adaptor (1) To determine the C flue system in configura- This kit allows an Immergas boiler to be installed and caps (6) on the wall and assemble the flue tions other than that described (Fig. 1-23) in "C...
  • Page 17: Ducting Of Flues Or Technical Slots

    Ø 80 flexible “Green Range” ducting systems must 1.16 CONFIGURATION TYPE B, OPEN The thermo-fluid dynamic features (flue flow only be used for domestic use and with Immergas CHAMBER AND FAN ASSISTED FOR rate, % of carbon dioxide, % humidity etc..) of condensing boilers.
  • Page 18: Flues, Chimneys, Chimney Pots And Terminals

    1.18 FLUES, CHIMNEYS, CHIMNEY POTS 1.21 GAS SYSTEM START-UP. AND TERMINALS. To start up the system, refer to the technical The flues, chimneys and chimney pots for the standard in force. evacuation of combustion products must be in In particular, for new gas systems: compliance with applicable standards.
  • Page 19: Circulation Pump

    1.23 CIRCULATION PUMP. • System circulator pump. The system circulator most heating systems, proving particularly The boilers are supplied with 2 circulator pumps, pump controls the room heating or cooling re- suitable in single-pipe and two-pipe installa- both equipped with speed regulator. quests downstream of the hydraulic manifold.
  • Page 20: Kits Available On Request

    Head available to the system. 1-26 Constant head (ΔP C). Flow rate (l/h) Key: A = Head available at speed 2 ÷ 7 Proportional head (ΔP V). B = Power absorbed by the system circulator pump (dotted area) Flow rate (l/h) 1.24 KITS AVAILABLE ON REQUEST.
  • Page 21: Boiler Components

    1.25 BOILER COMPONENTS. 1-27 17 - Sample points (air A) - (flue gas F) 18 - Flue safety thermostat 19 - Heat exchanger safety thermal fuse 20 - System vent tank air valve Key: 21 - System vent tank 1 - System filling valve 22 - Ignition electrodes 2 - Condensate drain trap 23 - Fan...
  • Page 22: Use And Maintenance Instructions

    USE AND MAINTENANCE 2.2 GENERAL WARNINGS. - do not touch the appliance with wet or moist Never expose the wall-mounted boiler to direct parts of the body; do not touch when bare- INSTRUCTIONS vapours from a cooking surface. foot; 2.1 CLEANING AND MAINTENANCE. Use of the boiler by unskilled persons or children - never pull electrical cables or leave the appli- Attention: to preserve the boiler's integrity...
  • Page 23: Description Of Functioning States

    2.4 DESCRIPTION OF FUNCTIONING STATES Below find a list of boiler functioning states that appear on the multifunction display (24) by means of the indicator (6) with a brief descrip- tion. Refer to the instruction book for a complete explanation. Display (6) Description of functioning states Summer functioning mode without request in progress.
  • Page 24: Using The Boiler

    , to the external probe sup- heating is managed by the external probe de- heating the environment. Depending on the plied as standard and combined with the Immergas pending on the external temperature measured climatic conditions and on the set-point, the heat pump supplied separately.
  • Page 25: Troubleshooting

    2.6 TROUBLESHOOTING. The boiler signals any anomalies via the flashing symbol (5) along with the “ERRxx” indication on the indicator (6) where “xx” corresponds to the error code described in the following table. The error code will be displayed on the remote panel via the same numeric code represented according to the following example: CAR = Exx.
  • Page 26 Error Anomaly signalled Cause Boiler status / Solution Code External probe miss- In the event the external probe is not connected or is faulty, the Check the external probe connection (1) ing or faulty anomaly is indicated. (3). Check the type of anomaly directly on the remote panel display (see relative instruc- tions manual).
  • Page 27: Parameters And Information Menu

    2.7 PARAMETERS AND INFORMATION technician and for which a password is required MENU. (See “Maintenance” chapter). By pressing the button "D" it is possible to access By turning the central heating temperature se- a menu divided into three main parts: lector switch (3) scroll through the menu items.
  • Page 28: Boiler Shutdown

    1 and 1.2 bar. If the pressure falls below 1 bar (with the circuit of the Immergas Anti-freeze Kit in the boiler. In cold) restore normal pressure via the valve located the case of prolonged inactivity (second case), we also recommend that: at the bottom of the boiler (Fig.
  • Page 29: Boiler Commissioning (Initial Check)

    BOILER COMMISSIONING - check that the common parameters between - ensure activation of all adjustment devices; the heat pump and the boiler are configured (INITIAL CHECK) - seal the gas flow rate regulation devices (if set- properly; tings are modified); To commission the boiler: - switch the boiler on and check correct ignition;...
  • Page 30: Boiler Hydraulic Diagram

    3.2 BOILER HYDRAULIC DIAGRAM. Key: 1 - Condensate drain trap 2 - Water inlet filter* 3 - Domestic hot water flow meter 4 - Domestic hot water flow rate adjuster 5 - Domestic hot water probe 6 - Gas valve 7 - Gas valve outlet pressure point (P3) 8 - Boiler circulator pump 9 - Vent valve...
  • Page 31: Installation Example Hydraulic Diagram

    3.3 INSTALLATION EXAMPLE HYDRAULIC DIAGRAM . SYSTEM WATER-DHW NET- CENTRAL HEATING WORK COOLING Key: AC - Domestic hot water outlet 1 - Boiler AF - Domestic cold water inlet 2 - External temperature probe RHT - Return to heat pump 3 - Comando amico remoto remote control (CAR MHT - Flow from heat pump...
  • Page 32: Converting The Boiler To Other Types Of Gas

    (e.g. Authorised extraction systems, with horizontal concentric Magis Victrix ErP Technical After-Sales Service). pipe measuring more than 1 metre. To convert to another type of gas the following...
  • Page 33: Adjustment Of The Air-Gas Ratio

    At every adjustment variation on the screw 12 it is necessary to wait for the boiler to stabilise itself at the value set (about 30 sec.). Magis Victrix ErP at nominal at minimum output...
  • Page 34: Programming The P.c.b

    - “M5” configurations, menu reserved for the By turning the central heating temperature se- lector switch (3) scroll through the menu items. The Magis Victrix ErP boiler is set up for possible technician and for which a password is re- programming of several operating parameters.
  • Page 35 M5 menu (password must be entered) Value Default 1st Level 2nd Level Options Description set by the value technician In winter mode the pump is always powered and so functions continu- P67.1 ously In winter mode the pump is managed by the room thermostat or by the P67.2 P67.2 remote control...
  • Page 36 M5 menu (password must be entered) Value Default 1st Level 2nd Level Options Description set by the value technician RELE3-0 Relay 3 not used Check the storage tank recirculation pump RELE3-1 (not used on this model) The relay signals the intervention of boiler block ( Can be coupled to an RELE3-2 external signalling device, not supplied) The relay signals that the boiler is in heating or cooling request mode (the...
  • Page 37: Central Heating Operation In

    3.10 CENTRAL HEATING OPERATION IN COMBINATION WITH THE HEAT PUMP. Following a request during the room heating mode, the electronics decide, according to the external temperature, whether to activate the heat pump, or (with cold or high temperatures) the boiler (fig. 3-6): Boiler and heat pump can even operate simulta- neously: in fact, if only the heat pump is active, but it cannot bring the water to temperature...
  • Page 38: Chimney Sweep" Function

    3.11 "CHIMNEY SWEEP" FUNCTION. 3.17 SOLAR PANELS COUPLING - Check that the system static pressure (with If this function is activated it takes boiler func- FUNCTION. system cold and after refilling the system by tioning to the adjustable power of the central The boiler is set-up to receive pre-heated water means of the filling valve) is between 1 and 1.2 heating selector switch.
  • Page 39: Casing Removal

    3.19 CASING REMOVAL. - remove the sides (7) loosening the screws (8), To facilitate boiler maintenance the casing can push slightly upwards in order to release the be completely removed as follows: side from the seat (9) and pull towards yourself - Remove the lower protection plate (10) by (see figure);...
  • Page 40: Variable Heat Output

    3.20 VARIABLE HEAT OUTPUT. chamber (see pressure test 15 and 16 Fig. 1-27). measuring 0.5 m in length. Gas flow rates refer N.B.: the pressures indicated in the table repre- The adjustments must be made with a digital to the lower calorific value at a temperature of sent the differences of pressures at the ends of differential pressure gauge with scale in tenths 15°C and at a pressure of 1013 mbar.
  • Page 41: Technical Data

    3.22 TECHNICAL DATA. Domestic hot water nominal heat input kW (kcal/h) 26.7 (22980) Central heating nominal heat input kW (kcal/h) 24.1 (20738) Minimum heat input kW (kcal/h) 3.3 (2815) Domestic hot water nominal heat output (useful) kW (kcal/h) 26.0 (22360) Central heating nominal heat output (useful) kW (kcal/h) 23.6 (20296)
  • Page 42: Key For Data Nameplate

    3.23 KEY FOR DATA NAMEPLATE. Cod. Md Sr N° Cod. PIN Type n min. max. n min. n max. Class CONDENSING N.B.: the technical data is provided on the data plate on the boiler Model Cod. Md Model code Sr N° Serial Number Check Cod.
  • Page 43: Technical Parameters For Combination Boilers (In Compliance With Regulation 813/2013)

    Contact information IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY (*) High temperature mode means 60°C on return and 80°C on flow. (**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return tempera- ture.
  • Page 44: Parameters For Filling In The Package

    Use sheet fig. 3-10 for “assemblies” related to In case you should wish to install an assembly, the heating function (e.g.: boiler + temperature starting from the Magis Victrix ErP boiler, use controller). the package fiche in fig. 3-10 and 3-12.
  • Page 45 Parameters for filling in the assembly chart. Parameter Magis Victrix ErP ‘I’ ‘II’ ‘III’ 1,11 ‘IV’ 0,43 * to be established by means of table 5 of Regulation 811/2013 in case of “assembly” including a heat pump to integrate the boiler. In this case the boiler must be considered as the main appliance of the assembly.
  • Page 46 Facsimile for filling in domestic hot water production system package fiche. Water heating energy efficiency of combination heater ‘I’ Declared load profile: Solar contribution From fiche of solar device Auxiliary electricity ( 1,1 ‘I’ 10 % ) ‘II’ ‘III’ ‘I’ Water heating energy efficiency of package under average climate Water heating energy efficiency class of package under average climate <...
  • Page 47 Parameters for filling in DHW package assembly chart. Parameter Magis Victrix ErP ‘I’ ‘II’ ‘III’ * to be determined according to Regulation 811/2013 and transient calculation methods as per Notice of the European Community no. 207/2014. 3-12 Domestic hot water production system package fiche.
  • Page 48 Follow us Immergas Italia immergas.com Immergas S.p.A. 42041 Brescello (RE) - Italy Tel. 0522.689011 Fax 0522.680617 Certified company ISO 9001 ИЗКЛЮЧИТЕЛЕН ПРЕДСТАВИТЕЛ И СЕРВИЗ АМАКС ГАЗ ООД 1261 Мрамор, София ул В. Левски 148 Tel. 0700 112 66 Fax 02 902 46 70...