Available languages

Activation temperature for the auxiliary contact {10125} {10179} (3°C)
Deactivation temperature for the auxiliary contact {10126} {10180} (5°C)
8.4.12.9
Contacts activated on the battery's state of charge (SOC) {10128} {10182} (only available
in the presence of a BSP) (menu)
You can activate the auxiliary contacts according to the state of charge of the battery (SOC). If the
SOC falls below the set level, the contact will be activated. A time period can be associated with
the SOC level to stipulate that the battery must be below the set level a certain time before the
contact is activated. The contact is deactivated when the battery's SOC rise above the pre-set level
which can also be associated with a time period. The contact may also be deactivated when the
battery reaches the floating phase.
Contact activated at SOC 1 {10129} {10183} (no)
Contact activated below SOC 1 {10130} {10184} (50%)
Duration 1 {10131} {10185} (12h)
Contact activated at SOC 2 {10132} {10186} (no)
Contact activated below SOC 2 {10133} {10187} (30%)
Duration 2 {10134} {10188} (0.25h)
Contact activated at SOC 3 {10135} {10189} (no)
Contact activated below SOC 3 {10136} {10190} (90%)
Duration 3 {10137} {10191} (0.25h)
Contact deactivated below SOC {10138} {10192} (90%)
Deactivation time {10139} {10193} (0.25h)
Deactivation if the battery is in floating phase {10140} {10194} (no)

9 ACCESSORIES

9.1 R
EMOTE CONTROL AND PROGRAMMING CENTRE
This accessory is an important complement to the VarioTrack. It can be connected via one of the
two communication connectors "Com. Bus" (7) (see chap. 4.1 "Elements of the cable compartment")
thanks to the cable supplied with the remote control.
When the remote control RCC-02/-03 is connected to another compatible device
(Xtender, VarioString, BSP, Xcom or other) with the same communication bus it is possible
that the software versions are not compatible. It is highly recommended to make a
software update of all components in the system in order to guarantee all functionalities.
Therefore, before starting the setup of the device, download the latest software version
from our website: www.studer-innotec.com on an SD card. Follow the instructions in the
RCC manual for a successful installation.
These connectors must be used only to connect a compatible Xtender accessory,
excluding any other type of connection such as LAN, Ethernet, ISDN, etc.
The remote control RCC-02/-03 is compatible with the following equipment:
solar charge controller MPPT
VarioTrack
solar charge controller MPPT
VarioString
Xtender
inverters/chargers
When it is connected to at least one of these two devices, it also allows interacting with the other
peripherals of an Xtender system, i.e.:
Battery Status Processor:
RS 232 communication interface:
Internet based communication sets:
Manuel utilisateur
BSP-500/BSP1200
Xcom-232i
Xcom-LAN, Xcom-GSM
V 4.0
RCC-02/-03
.
Studer Innotec SA
VarioTrack
41

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Variotrack vt-65Variotrack vt-80

Table of Contents