8.4 D
ESCRIPTION OF THE
The parameters of the VarioTrack can be modified in the menu "VarioTrack MPPT settings" of the RCC
remote control.
This menu allows accessing the following 3 under-menus:
BASIC SETTINGS: where the most common parameters to be set when commissioning are found.
BATTERY MANAGEMENT AND CYCLE: where all the parameters can be set, defining in detail the
battery cycle during all its phases.
SYSTEM MENU: gathering a few parameters that are not directly related to the battery cycle, such as
backing up and restoring the system, resetting, monitoring setting, etc.

8.4.1 Convention

Functions and values of the parameters mentioned in this manual are described in this chapter. Each
parameter is defined by a short description, a number {xxxxx} followed by its value and unit by default
(xxxxx). The type of parameter (menu, signal) replaces the value between brackets when this latter
does not exist. The RCC menus are also identified by a name and a number {xxxxx} that can be
found, as per the parameter number, on the top right-hand corner of the RCC screen.

8.4.2 Parameter access level

All the parameters described hereafter are accessible through 2 different access levels. In factory
configuration, only a few of them are accessible through the "basic menu". To access all the other
menus and parameters, the RCC must be configured at the "Expert" level following the procedure
given in the RCC manual, chapter "
Each parameter can be placed at a different level (for example, from level "Expert" to level "Basic").
In this case, the parameter is accessible also when the RCC is set to basic mode. For more information
on this subject, refer to chapter "I

8.4.3 Organisation of the configuration menu

Level
Nr
VarioTrack parameter description
Basic
10000 BASIC SETTINGS
Expert
10054
Block manual programming (dip-switch)
Basic
10001
Voltage of the system
Basic
10037
Synchronisation battery cycle with Xtender
Basic
10005
Floating voltage
Basic
10009
Absorption voltage
Basic
10017
Equalization allowed
Basic
10021
Equalization voltage
Basic
10056
Restore default settings
Inst.
10057
Restore factory settings
Expert
10344 CONFIGURATION OF BIDIRECTIONAL MODE
Expert
10345
Choice of Charger or Boost mode
Expert
10003 BATTERY MANAGEMENT AND CYCLE
Basic
10037
Synchronisation battery cycle with Xtender
Expert
10002
Battery charge current
Expert
10334
Battery undervoltage
Expert
10036
Temperature compensation
Expert
10004
Floating phase
Basic
10005
Floating voltage
Expert
10006
Force phase of floating
Expert
10007
Absorption phase
Expert
10008
Absorption phase allowed
30
V
T
ARIO
RACK PARAMETERS
" (p. 22).
USER LEVEL
,
NSTALLER
LEVEL OF USE AND ACCESSIBILITY
V 4.0
" p.39 in the RCC manual.
Factory value
No
Automatic
Yes
13.6/27.2/54.4 Vdc
14.4/28.8/57.6 Vdc
No
15.6/31.2/62.4 Vdc
Charger
Yes
80 Adc
10/20/40 Vdc
-3 mV/°C/cell
13.6/27.2/54.4 Vdc