13 PRODUCT RECYCLING

The VarioTrack meets the European directive 2011/65/EU on
hazardous substances and does not contain the following
elements: lead, cadmium, mercury, hexavalent chrome, PBB or
PBDE.
To dispose of this product, please use the service for the collection
of electrical waste and observe all obligations in force in the place
of purchase.

14 EU DECLARATION OF CONFORMITY

The charge regulator described in this manual has been designed and manufactured in accordance
with the following directives and harmonized standards.
Low Voltage Directive (LVD) 2014/35/EU
- EN 50178:1997
Electromagnetic Compliance (EMC) Directive 2014/30/EU
- EN 61000-6-1:2007
- EN 61000-6-2:2005 /AC:2005
- EN 61000-6-4:2007/A1:2011

15 TROUBLESHOOT

Mes.
nr
Messages description
0
Warning (000): Battery low
12
(012): Use of battery temperature sensor
14
Halted (014): Over temperature EL
16
Warning (016): Fan error detected
20
Halted (020): Battery overvoltage
80
Halted (080): No battery (or reverse polarity)
81
Warning (081): Earthing fault
82
Halted (082): PV overvoltage
48
Troubleshoot
The battery voltage has been below the
battery undervoltage level set by {10334} for
more than 30 seconds. The device will not
turn off.
Indicates the presence of a BTS-01
temperature probe connected to the device
that sent the message.
The device is stopped after surpassing the
max internal electronics temperature.
The external ventilation module (ECF-01) is
defective or has been disconnected during
the functioning of the device.
Slow or fast battery overvoltage
The battery voltage must be greater than 3V
in order for it to be detected.
The configured limits for the earth potential
have been exceeded. The wiring of the
installation should be verified.
The converter has stopped as the PV voltage
limit is exceeded. The sizing of the module
chains must be verified. Exceeding the
permitted voltage can seriously damage the
device.
V 4.0