Displaying The Operating Mode Of The Equipment (Info N° 11016) - Studer VarioTrack VT-40 User Manual

Hide thumbs Also See for VarioTrack VT-40:
Table of Contents

Advertisement

Available languages

Available languages

11008
kWhR
11009
MWhT
11010
Cd-1
11011
Ed-1
11015*
Type
11016*
Mode
11017*
PVmx
11018*
Ibmx
11019*
PVxP
11020
Bmax
11021
Bmin
11025*
Sd
11026*
Sd-1
11034*
Err
11037
EqIn
11038
Phas
11066
Sync
11069
VT state
11076
locEr
11082
RME
11083
Tbox
11085*
Error
11086*
Mode
11087
Redy
*these values can't be displayed in the multi-unit display. They will be visible while going in the sub-
screen of the Multi-unit display, showing every unit individually.
8.2.1.2
Displaying the triggering source of the auxiliary relays
To view the actual triggering source of the two auxiliary relays, press the SET button and use the
up/down arrows to navigate down to the two relay fields (b). Select one of the two relays and press
SET to view the information indicating the cause of the last relay activation (if the relay is presently
activated) or deactivation (if the relay is presently deactivated. The display also shows the logic
combination mode: AND or OR.
To exit the selected relay field, press ESC.
These information fields are visible even if the auxiliary relay ARM-02 see chapter 9.3, is not
connected.
8.2.2 Displaying the operating mode of the equipment (Info n° 11016)
Night: the solar generator voltage (or luminous intensity) is not enough to start the equipment. When
this indication appears during the day, it means a generator fault (wiring).
StartUp: the solar generator (or luminous intensity) is not enough to start the equipment but sufficient
to produce power. This indication only appears in the morning or in the evening.
Charger or Charge: the charger operates normally at the maximum power point of the solar
generator
Manuel utilisateur
kWh
Produced energy resettable counter
MWh
Total produced energy
Ah
Production in (Ah) for the previous day
kWh
Production in (Wh) for the previous day
Text
Model of VarioTrack (VT-80, VT-65, VT-30, VT-HV)
Operating mode (Night, StartUp, ---, Charger, ---, Security, OFF,
Text
---, Charge, Charge V, Charge I, Charge T, Ch. Ibsp)
Vdc
Max PV voltage for the current day
Adc
Max battery current of the current day
kW
Max power production for the current day
Vdc
Max battery voltage for the current day
Vdc
Min battery voltage for the current day
h
Number of irradiation hours for the current day
h
Number of irradiation hours for the previous day
Type of error (No Error, BatOverV, Earth, No Batt, OverTemp,
Text
BatOverV, PvOverV, Others, ---, ---, ---, ---, HardErr)
days
Number of days before next equalization
Battery cycle phase (Bulk, Absorpt., Equalize, Floating, ---, ---,
Text
R.float., Per.abs., ---, ---, ---, ---)
Synchronisation state (---, ---, ---, ---, XTslave, VTslave, ---, ---,
Text
VTmaster, Autonom., VSslave, VSmaster)
Text
State of the VarioTrack (Off, On)
Local daily communication error counter (CAN)
Text
Remote entry state (RM EN 0, RM EN 1)
°C
Internal temperature of the box
Type of error (No Error, BatFaOV, Earth, No Batt, OverTemp,
Text
BatOver, HdcOverV, HdcShort, ---, BatUC, ---, BatOC, HardErr,
BatUV, MotorOL, StartErr)
Text
Operating mode (Error, OFF, Night, Solar, Catenary, Boost)
Text
Motor running allowed (No, Yes)
V 4.0
Studer Innotec SA
VarioTrack
27