16 PARAMETER LIST

Level
Nr
VarioTrack parameter description
Basic
10001 Voltage of the system
Expert
10002 Battery charge current
Basic
10005 Floating voltage
Expert
10006 Force phase of floating
Expert
10008 Absorption phase allowed
Basic
10009 Absorption voltage
Expert
10010 Force absorption phase
Expert
10011 Absorption duration
Expert
10012 End of absorption triggered by the current
Expert
10013 Current threshold to end absorption phase
Basic
10017 Equalization allowed
Expert
10018 Force equalization
Expert
10019 Equalization before absorption phase
Expert
10020 Equalization current
Basic
10021 Equalization voltage
Expert
10022 Equalization duration
Expert
10025 Days between equalizations
Expert
10026 End of equalization triggered by the current
Expert
10027 Current threshold to end equalization phase
Expert
10029 Force a new cycle
Expert
10030 Voltage level 1 to start a new cycle
Time period under voltage level 1 to start a new
Expert
10031
cycle
Expert
10032 Voltage level 2 to start a new cycle
Time period under voltage level 2 to start a new
Expert
10033
cycle
Expert
10034 Cycling restricted
Expert
10035 Minimal delay between cycles
Expert
10036 Temperature compensation
Basic
10037 Synchronisation battery cycle with Xtender
Expert
10039 ON of the VarioTrack
Expert
10040 OFF of the VarioTrack
Expert
10043 Reset daily solar production meters
Expert
10044 Reset daily min-max
Expert
10051 Reset of all VarioTrack
Expert
10052 Equalization with fixed interval
Expert
10053 Open circuit ratio -> MPP
Expert
10054 Block manual programming (dip-switch)
Basic
10056 Restore default settings
Inst.
10057 Restore factory settings
Inst.
10058 Parameters saved in flash memory
Expert
10060 Check Earthing
Expert
10075 Type of MPP tracking
Expert
10085 Battery overvoltage level
Expert
10086 Restart voltage level after a battery overvoltage
Inst.
10087 Disabling of the display button
Expert
10089 Operating mode (AUX 1)
50
V 4.0
Factory value
Automatic
80 Adc
13.6/27.2/54.4 Vdc
-
Yes
14.4/28.8/57.6 Vdc
-
120 min
No
10 Adc
No
-
Yes
80 Adc
15.6/31.2/62.4 Vdc
30 min
26 days
No
10 Adc
-
12.2/24.4/48.8 Vdc
30 min
11.8/23.6/47.2 Vdc
2 min
Yes
1 hours
-3 mV/°C/cell
Yes
-
-
-
-
-
Yes
80 %
No
-
-
Yes
No control
P&O
17/34.1/68.2 Vdc
16.2/32.4/64.8 Vdc
No
Automatic
User manual
User
value