Delta VFD004L11A User Manual page 84

Compact and panel-installation drives
Table of Contents

Advertisement

Send Quote Requests to info@automatedpt.com
SPECIFICATIONS
Voltage Class
Model Number VFD-
Applicable Motor Output (kW)
Rated Output Capacity (KVA)
Rated Output Current (A)
Max. Output Voltage (V)
Rated Frequency (Hz)
Rated Input Current (A)
Input voltage Tolerance
Frequency tolerance
Control system
Output Frequency Resolution
Torque Characteristics
Overload Endurance
Accel/Decel Time
V/F pattern
Stall Prevention Level
Frequency
Setting
Operation
Setting
Signal
Multi-function Input Signal
Multi-function Output Signal
Other Function
Protection
Other
Cooling
Installation Location
Ambient Temperature
Storage Temperature
Ambient Humidity
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
L
A/B
002
0.2
0.6
1.6
3-phase corresponds
to double input voltage
6
Single phase
90~132V 50/60Hz
Including the auto-torque, auto-slip compensation, starting torque can be
Keypad
Potentiometer-5KΩ/0.5W, DC 0 ~ +10V (input impedance 100KΩ), 4~20mA
External Signal
(output impedance 250Ω), multi-function inputs1 to 3 (3steps, JOG,
UP/DOWN command), communication setting
Keypad
M0,M1,M2,M3 can be combined to offer various modes of operation,
External Signal
Multi-step selection 0 to 3, Jog, accel/decel inhibit, first/second accel/decel
switch, counter, PLC Operation, external Base Block (NC,NO) selection
AC Drive Operating, Frequency Attained, Non-zero speed, Base Block,
Fault Indication, Local/Remote indication, PLC Operation indication.
AVR, S-curve, Over-Voltage Stall Prevention, DC Braking, Fault Records,
Adjustable Carried Frequency, Starting Frequency Setting of DC Braking ,
Over-Current Stall Prevention, Momentary Power Loss restart, Reverse
Over Voltage, Over Current, Under Voltage, Overload, Electronic thermal,
Altitude 1,000 m or below, keep from corrosive gasses, liquid and dust
Vibration
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
115V
004
002
0.4
0.2
1.0
0.6
2.5
1.6
Three-phase corresponds to input voltage
9
4.9/1.9
SVPWM (Sinusoidal Pulse Width Modulation, carried frequency
3kHz~10kHz)
150% at 5 Hz
150% of rated current for 1 minute
0.1~600Sec. (can be set individually)
V/F pattern adjustable
20~200%, setting of Rated Current
Setting by
Setting by RUN//STOP keys
RS-485 communication port
Inhibition, Frequency Limits, Parameter Lock/Reset
Overheating, Self-testing
Including EMI Filter
Forced air-cooling
-10 -40
(Non-Condensing and not frozen)
-20
Below 90%RH (non-condensing)
2
9.80665m/s
(1G) less than 20Hz, 5.88m/s
A-1
230V
004
007
0.4
0.7
1.0
1.6
2.5
4.2
1.0~400Hz
6.5/2.7
9.7/5.1
Single / 3-phase
180~264V 50/60Hz
±5%
0.1Hz
ð
keys or V.R
to 60
2
(0.6Gat) 20 to 50Hz
VFD-L Series
015
1.5
2.7
7.0
*/9
3-phase
180~264V
50/60Hz
A

Advertisement

Table of Contents
loading

Table of Contents