Mid-Point Voltage (Vmid)
Settings
The parameter sets the Mid-Point Voltage of any V/F curve. With this setting, the V/F
ratio between Minimum Frequency and Mid-Point Frequency can be determined. This
parameter must be equal to or greater than Minimum Output Voltage (Pr.1-06) and equal
to or less than Maximum Output Voltage (Pr.1-02).
1 - 05
Minimum Output Frequency (Fmin)
Settings
This parameter sets the Minimum Output Frequency of the AC drive. This parameter
must be equal to or less than Mid-Point Frequency (Pr.1-03).
1 - 06
Minimum Output Voltage (Vmin)
Settings
This parameter sets Minimum Output Voltage of the AC drive. This parameter must
be equal to or less than Mid-Point Voltage (Pr.1-04).
1 - 07
Upper Bound of Output Frequency
Settings
This parameter must be equal to or greater than the Lower Bound of Output Frequency
(Pr.1-08). The Maximum Output Frequency (Pr.1-00) is regarded as 100%.
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
d 2.0 to d 255V
d 1.0 to d 60.0Hz
d 2.0 to d 255V
V o lta g e
P r.1 - 0 2
P r.1 - 0 4
P r.1 - 0 6
0
P r.1 - 0 3
P r.1 - 0 5
S ta n d a rd V /F C u rv e
d 1 to d110%
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Factory Setting: d12.0
Factory Setting: d12.0
F re q .
P r.1 - 0 0
P r.1 - 0 1
Factory Setting: d 100
5-5
VFD-L Series
Unit: 0.1V
Factory Setting: d 1.0
Unit: 0.1Hz
Unit: 0.1V
Unit: 1%
5

Advertisement

Table of Contents
loading

Table of Contents