Group 9: Communication Parameters

9 - 00
Communication Address
Settings d 1 to 247
This parameter can be set during operation.
If the AC drive is controlled by RS-485 serial communication, the communication
address must be set via this parameter.
9 - 01
Transmission Speed
Settings
This parameter can be set during operation.
Users can set parameters and control the operation of the AC drive via the RS-485
serial interface of a personal computer. This parameter is used to set the transmission
speed between the computer and AC drive.
9 - 02
Transmission Fault Treatment
Settings
R S 4 8 5
C o m p u te r
d 1
V F D - L
d 0
Baud rate 4800 (data transmission speed: bits / second)
d 1
Baud rate 9600 (data transmission speed: bits / second)
d 2
Baud rate 19200 (data transmission speed: bits / second)
d 0
Warn and keep operating
d 1
Warn and RAMP to stop
d 2
Warn and COAST to stop
d 3
No Warning and keep operating
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
d 3
d2
V F D - L
V F D - L
5-40
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
Factory Setting: d 1
Factory Setting: d 1
Factory Setting: d 0