Group 3: Output Function Parameters

3 - 00
Desired Frequency Attained
Settings
If a Multi-function output terminal is set to function as Desired Frequency Attained
(Pr.3-03=d9), then the output will be activated when the programmed frequency is
attained.
3 – 01
Terminal Count Value
Settings
The parameter determines the value of the internal counter. The internal counter can be
triggered by the external terminal (Pr.4-4 to Pr.4-6, d18). Upon completion of counting,
the specified output terminal will be activated. (Pr.3-03=d14).
3 – 02
Preliminary Count Value
Settings
When the counter value is counted up from "1" to the setting value of this parameter, the
corresponding multi-function output terminal will be closed, when sets d15 as desired
value attained setting. The application can be that closing the multi-function output
terminal makes the AC drive operate at low speed until stop before the counting value is
going to be attained.
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
d 1.0 to d 400 Hz
F re q .
D e te c tio n ra n g e
M a x . O u tp u t
F re q .
+
-
2 H z
D e s ire d F re q .
P r.3 - 0 2
P r e s e t F r e q .
A tta in e d
in d ic a ti o n
O F F
P r.3 - 0 3
D e s ir e d F re q .
A tta in e d
O F F
In d ic a tio n
P r.3 - 0 3
D e s ire d F re q . A tta in e d & P re s e t F re q . A tta in e d
d 0 to d 999
d 0 to d 999
5-13
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Factory Setting: d 1.0
D e te c tio n ra n g e
+
4 H z
-
D e te c tio n
ra n g e
-2 H z
T im e
O F F
O N
O N
O F F
VFD-L Series
Unit: 0.1Hz
Factory Setting: d 0
Factory Setting: d 0
5