VFD-L Series
Parameters
1-06
1-07
1-08
1-09
1-10
1-11
1-12
1-13
1-14
1-15
1-16
1-17
1-18
Group 2: Operation Method Parameters
Parameters
2-00
2-01
2-02
2-03
Functions
Minimum output voltage 2.0 ~ 255V
Upper bound of freq.
Lower bound of freq.
Accel time 1 (Tacc1)
Decel time 1 (Tdec1)
Accel time 2
Decel time 2
JOG Accel time
JOG Decel time
JOG frequency
Auto-accel/decel
S-curve setting in
acceleration
S-curve setting in
deceleration
Functions
Source of frequency
command
Source of operation
command
Stop method
Carrier freq.
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Settings
1 ~ 110%
0 ~ 100%
0.1 ~ 600 Sec
0.1 ~ 600 Sec
0.1 ~ 600 Sec
0.1 ~ 600 Sec
0.1 ~ 600 Sec
0.0 ~ 600 Sec
1.0Hz~400Hz
0: Linear Accel/Decel
1: Auto accel, linear decel
2: Linear accel, auto decel,
3: Auto Accel/Decel
4: Linear accel. Auto decel, stall
prevention during deceleration
5: Auto accel. Linear decel, stall
prevention during deceleration
0 ~ 7
0 ~ 7
Settings
0: Digital keypad
1: 0 ~ 10V from AVI
2: 4 ~ 20mA from AVI
3: Controlled by V.R on drive
4: RS-485 communication interface
0: By digital keypad
1: By external terminals, keypad STOP
enable
2: By external terminals, keypad STOP
disable
3: By RS-485 communication interface,
keypad STOP enable
4: By RS-485 communication interface,
keypad STOP disable
0: Ramp stop
1: Coast stop
3 ~10K Hz
8-2
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
Factory
Setting
12.0
100
0.0
10.0
10.0
10.0
10.0
10.0
10.0
6.0
0
0
0
Factory
Setting
0
0
0
10

Advertisement