VFD-L Series
Parameters Functions
4-04
4-05
4-06
Group 5: Multi-step Speed and PLC Parameters
Parameters
5-00
5-01
5-02
5-03
5-04
5-05
5-06
5-07
5-08
Multi-function input
terminal1 (M0, M1)
(d 0 d 20)
Multi-function input
terminal 2(M2)
Multi-function input
terminal 3(M3)
(d 0, d 4 d 20)
Functions
st
1
step speed freq.
nd
2
step speed freq.
rd
3
step speed freq.
PLC mode
PLC
forward/reverse
motion
Time duration step 0
Time duration step 1
Time duration step 2
Time duration step 3
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Settings
0: not used
1: M0: FWD/STOP, M1:REV/STOP
2: M0: FWD/REV, M1:RUN/STOP
3: M0, M1, M2: 3-wire operation control
mode
4: External fault, normally open (N.O.)
5: External fault, normally closed (N.C.)
6: RESET
7: multi-step speed command 1
8: multi-step speed command 2
9: jog operation
10: accel/decel speed inhibit
11: first or second accel/decel time selection
12: base-block (B.B.),normally open (N.O.)
13: base-block (B.B.),normally closed (N.C)
14: increase master freq.
15: decrease master freq.
16: run PLC program
17: pause PLC
18: counter trigger signal
19: counter reset
20: select ACI/deselect AVI
Settings
0.0 ~ 400Hz
0.0 ~ 400Hz
0.0 ~ 400Hz
0: Disable PLC operation
1: Execute one program cycle
2: Continuously execute program cycles
3: Execute one program cycle step by
step (separate by STOP)
4: Continuously execute one program
cycle step by step (separate by
STOP)
0 ~ 15 (0: Forward 1: Reverse)
0 ~ 65500 Sec
0 ~ 65500 Sec
0 ~ 65500 Sec
0 ~ 65500 Sec
8-4
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
Factory
setting
1
6
7
Factory
Setting
0.0
0.0
0.0
0
0
0
0
0