reset counters interface null
Use reset counters interface null to clear the statistics on the null interface.
Syntax
reset counters interface [ null [ 0 ] ]
Views
User view
Predefined user roles
network-admin
Parameters
0: Specifies the number of the null interface, which is always 0.
Usage guidelines
To determine whether the null interface works correctly within a period by collecting the traffic statistics
within that period, first use the reset counters interface [ null [ 0 ] ] command to clear the statistics. Then
have the interface automatically collect the statistics.
Examples
# Clear the statistics on interface Null 0.
<Sysname> reset counters interface null 0
Related commands
display interface null
shutdown
Use shutdown to shut down a loopback interface.
Use undo shutdown to bring up a loopback interface.
Syntax
shutdown
undo shutdown
Default
A loopback interface is up.
Views
Loopback interface view
Predefined user roles
network-admin
Usage guidelines
Use the shutdown command with caution, because the command disconnects the connection of the
interface and disables the interface from communicating.
39