Ametek SurgeX Vertical+ Series User Manual
Ametek SurgeX Vertical+ Series User Manual

Ametek SurgeX Vertical+ Series User Manual

Switched ip controllable vertical pdu

Advertisement

Quick Links

SX-VS-128, SX-VS-1216, SX-VS-1624,
SX-VS-108i, SX-VS-1016i, SX-VS-1624i
Switched IP Controllable Vertical PDU
User Manual
© AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com | UM-Vertical Series-Rev-D

Advertisement

Table of Contents
loading

Summary of Contents for Ametek SurgeX Vertical+ Series

  • Page 1 SX-VS-128, SX-VS-1216, SX-VS-1624, SX-VS-108i, SX-VS-1016i, SX-VS-1624i Switched IP Controllable Vertical PDU User Manual © AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com | UM-Vertical Series-Rev-D...
  • Page 2 User Manual © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 3: Table Of Contents

    Sequences Setup ................................26 Utilities....................................... 27 4.5.1 File Upload ..................................27 4.5.2 Backup/Restore ................................28 4.5.3 Factory Reset .................................. 28 4.5.4 Soft Reboot ..................................28 Security ......................................29 5.1 Authentication ....................................29 © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 4 5.2.1 Network Interface ..................................29 Application Programming Interfaces (APIs) ............................30 HTTP/HTTPS REST ................................. 30 Interfaces ....................................30 Part Numbers ..................................... 31 Part Number Scheme ................................31 Troubleshooting ....................................32 9. Specifications ...................................... 33 © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 5: Introduction

    (16) IEC 13 (1) IEC C14 (1) RJ45, (1) USB-Micro AB (1) Push Button SX-VS-1624i (20) IEC 13 (4) IEC 19 (1) IEC 20 (1) RJ45, (1) USB-Micro AB (1) Push Button © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 6: Rated & Maximum Current

    SX-VS-128 SX-VS-1216 SX-VS-1624 SX-VS-108i SX-VS-1016i SX-VS-1624i 1.4 Voltage Requirements Model: Input Voltage SX-VS-128 120V AC SX-VS-1216 120V AC SX-VS-1624 120V AC SX-VS-108i 240V AC SX-VS-1016i 240V AC SX-VS-1624i 240V AC © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 7: Installation And Components

    HTTP at port 80. 2.5 LED Indicators The receptacles have individual power indicator LEDs (F). These are paralleled in the control interface. In addition, the unit has an LED indicating power (G). © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 8: Buttons

    V Series to the rack through the mounting holes (A) following the appropriate local regulations and requirements. 1. PDU (Quantity 1) 2. Mounting Brackets (Quantity 2) 3. 8-32 Mounting Bracket Screws (Quantity 8) 4. 10-32 Rackscrew Truss-Head - 4 Pieces (Quantity 4 pairs) © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 9: Step One

    4 bolts each bracket utilizing the threaded holes (Diagram A). Hint: The mounting brackets can be rotated in any direction to attach on the PDU Diagram B and C. Diagram A Diagram B Diagram C © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 10: Step Two

    User Manual 3.2 Step Two The supplied nuts, bolts and washers connect the V Series PDU to the DIN rail of the equipment rack. © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 11: Web Server

    Real Time Clock (RTC) synced to an Internet time server and backed up by an internal battery. For the most accurate time stamps and to eliminate clock drift, we suggest verifying the NTP connection. © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 12 Crest Factor Min Line Voltage The maximum crest factor calculated during the measurement period. Neutral -Ground Voltage Energy Usage Total Device The accumulated energy consumed by connected equipment during the measurement period. © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 13: Setup

    Create and modify Triggers Threshold with Samples Configure triggers based on measurements Auto Ping Configure triggers based on pinging IP addresses Schedule Configure triggers based on time Sequences Create and modify custom Sequences © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 14: Device Setup

    Hostname in an auto ping trigger. Auto Ping Timeout Specifies the amount of time the Vertical Series Plus device will wait for a ping response before calling the attempt a failure. © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 15 Useful for network appliances that may need to be rebooted, but otherwise want to be on all the time. Using this setting, the outlet will still turn off during Shutdown state. © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 16 The Outlet Group Configuration tab allows for the specification of visual feedback, and device initialization. Outlet Group Configuration Item Description Group Name Specifies the name label to be associated with the outlet group. Member Name Specifies the outlet members of this outlet group. © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 17 Time Zone Specifies the desired time zone adjustment for the Vertical Series Plus device. NTP Server Specifies the hostname or IP address of the NTP server to use for time synchronization. © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 18: Network Setup

    Specifies if the web server is enabled or disabled. NOTE: If disabling the web server, the web interface end REST API will be disabled, only limited functionality over SNMP will remain it enabled. HTTP Port Port number to use for the web server. © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 19: Network Advanced Setup

    Specifies which specific traps are to be sent. Triggers send traps for Triggering and Clearing. Manual Control sends traps for outlet state changes, and Authentication sends traps for failed authentication attempts. © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 20 Opens and hides a table with date/time coded 802.1x related messages for debugging an authentication failure. Authentication Type Specify the authentication method used during the 802.1x EAP negotiation. Different authentication options and settings will be displayed based on the selected Authentication Type. © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 21 A button to send an authentication request using the given settings for the user and password above. NOTE: Settings should be saved using the "Save Settings" button at the bottom of the page before testing a configuration change. © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 22: Triggers Setup

    REST API command. Clear Shutdown State Clear the device's shutdown state. Clearing the device's shutdown state will cause the outlets to follow the logic defined by the On Shutdown Clear setting. © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 23 The number of measurements out of the given number of samples being evaluated that must meet the criteria to trigger or clear the Trigger. Out Of 1-20 The number of consecutive measurements to be evaluated to trigger or clear the Trigger. © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 24 Fail Count Number of consecutive failed ping responses needed to trigger the Auto Ping trigger. Success Count Number of consecutive successful ping responses needed to clear the Auto Ping trigger. © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 25 Month January - December A month of the year to be used in the Annually trigger. Time 12:00 AM-11:59 PM A given time to be used in all scheduling triggers. © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 26: Users Setup

    Equipment On”. To run a sequence to test it, press “Run Sequence”. To edit an existing sequence, press the pencil icon. To delete a sequence, press the minus “-“ icon. © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 27: Utilities

    By default, V Series ships with a self-signed HTTPS certificate if HTTPS is enabled. A different certificate can be uploaded for use by the HTTPS server by selecting “HTTPS SSL Certificate” under the File type drop down. © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 28: Backup/Restore

    A soft reboot will not change the outlet state or disconnect power from connected equipment. This request will add a message in the event log “Rebooting Adapter Due to User Request”. © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 29: Security

    TLS 1.2 (HTTPS), as well as change its port. These settings also apply to the REST API. SNMP: Squid supports SNMP V3 for secure communications, with the ability to enable and disable. • © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 30: Application Programming Interfaces (Apis)

    SNMP V3 communications are intended to provide essential items for management. Read, Write, Table, and Trap objects will be included. Full protocol details, and the SNMP MIB, are available at https://www.ametekesp.com. © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 31: Part Numbers

    Rated Current 15A Max Current 15A Max Current 20A Max Current Number of Receptacles 8 Receptacles 16 Receptacles 24 Receptacles NEMA / IEC Model IEC Model (230V) NEMA Model (120V) © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 32: Troubleshooting

    7) Replacing a component or subsystem in the device without a trained technician may lead to device malfunctionn. 8) Contacting customer support - If the above troubleshooting methods do not resolve the issue, the user may be advised to contact customer support for further assistance. © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...
  • Page 33: Specifications

    • EN 61000-3-3:2013 • FCC 47 CFR PART 15 SUBPART B:2020 • ICES-003 ISSUE 6:2016-01 Updated 2019-04 IP protection class IPX0 AC Power System Type Pollution Rating Pollution degree (PD) PD 2 © 2023 AMETEK SurgeX | Technical Support 800-645-9721 | surgex.com...

Table of Contents