End-To-End Test Results - Paradyne 3610 Application Manual

Data service units time division multiplexer, multichannel multipoint, and digital bridge options
Hide thumbs Also See for 3610:
Table of Contents

Advertisement

COMSPHERE 3600 Series Data Service Units
Results
When the message Command Complete is displayed,
any key except the
key returns you to the End-to-
End Test submenu, where the Displ and Clr selections
appear.
When the test is over, the top line displays Final
instead of Active. Table 5-7 shows the information
provided by an End-to-End Test.
Results
Reported By
Time:
Local and
remote DBM
Tot Block:
Local and
remote DBM
Rx Blk err:
Local and
remote DBM
Tx Blk err:
Local and
remote DBM
Rx TimOuts:
Local DBM only
1
Local refers to the test initiator.
5-28
Figure 5-11. End-to-End Test
Tests originating from an NMS operating with DPII
protocol add the receive block errors to the receive
time-outs and return the results to NMS as receive block
errors.
For an example, refer to the COMSPHERE 3600 Series
Data Service Units, Models 3610 and 3611, Dial Backup
Module and SNA Diagnostic Interface Options,
Applications Guide.
Table 5-7

End-to-End Test Results

1
Running test timer. The Clr selection resets the timer to 0:00:00.
Number of blocks completed. The Clr selection resets the
counter to 0.
Number of incoming blocks with errors detected, indicating a
fault in the incoming transmission path. The Clr selection resets
the counter to 0.
Number of blocks with errors detected at the remote DSU,
indicating a fault in the outgoing transmission path. The Clr
selection resets the counter to 0.
Number of blocks that were not received or acknowledged by the
remote DBM. The Clr selection resets the counter to 0.
July 1999
Information Displayed