Leds - Paradyne 3610 Application Manual

Data service units time division multiplexer, multichannel multipoint, and digital bridge options
Hide thumbs Also See for 3610:
Table of Contents

Advertisement

P r t 2 : Enable
Enab
Disab
F1
F2
NOTE
If the DSU core is disabled,
enabling all ports in TDM or
MCMP mode will not enable the
DSU core. You must specifically
enable the DSU core.
P r t 2 : Disab
Command Complete
F1
F2
The local DBM can be enabled or disabled in the same
manner as for the ports.
In Remote mode, the following Transmitter Control
submenu appears:
Change TxCt l of:
Devic
Ports
F1
F2
Select Devic (Device) to enable or disable the DSU or
DBM. When selected, the address entered determines
whether the DSU or DBM is enabled or disabled. Select
Ports to enable or disable specific ports in Remote mode.
Select a port as previously demonstrated.
3610-A2-GB41-70
F3
F3
F3
July 1999

LEDs

The LEDs selection is only available from the Local
branch. This selection allows you to monitor any of the
TDM or MCMP ports at any given time. When a port is
selected, its lead activity is reflected in the DCP circuit
designation status indicators (TXD, RXD, etc.). The LEDs
on the TDM or MCMP circuit card show which ports are
being monitored when the TDM or MCMP mode is in
operation. You can also choose to monitor the aggregate
data stream.
To access LEDs from the top-level menu, make the
following selections:
Local (F1)
Ctrl
LEDs
LEDs Port:
Load
Save
F1
F2
Press the F1 key to select Load. The following
submenu appears:
LEDs Port:
F1
F2
Use the F1 ( ) or F2 ( ) keys to display the port
number of your choice. If you choose not to continue,
press the F3 key (Undo) to restore the prior port value,
then press the
key to return to the top-level menu.
DSU Operations
F3
1
Undo
F3
5-45

Advertisement

Table of Contents
loading

This manual is also suitable for:

3611Comsphere 3610Comsphere 3611Comsphere 3600 series

Table of Contents