Shutdown; Pressure Relief Procedure - Graco ProMix 2KS Operation

Plural component proportioner
Hide thumbs Also See for ProMix 2KS:
Table of Contents

Advertisement

Shutdown

Overnight Shutdown
1. Leave the power on.
2. Run Recipe 0 to purge solvent through meters and
gun.
Service Shutdown
1. Follow Pressure Relief Procedure on page 51.
2. Close main air shutoff valve on air supply line and
on ProMix.
3. Shut off ProMix 2KS power (0 position). F
4. If servicing EasyKey, also shut off power at main cir-
cuit breaker.
F
. 64. Power Switch
IG
312776B

Pressure Relief Procedure

NOTE: The following procedures relieve all fluid and air
pressure in the ProMix 2KS system. Use the procedure
appropriate for your system configuration.
Relieve pressure when you stop spraying, before
changing spray tips, and before cleaning, checking, or
servicing equipment.
Single Color Systems
. 64.
IG
1. While in Mix mode (gun triggered), shut off the A
and B fluid supply pumps/pressure pots. Close all
fluid shutoff valves at the pump outlets.
2. With the gun triggered, push the manual override on
the A and B dose valve solenoids to relieve pres-
sure. See F
0 = OFF
NOTE: If a Dose Time alarm (E-7, E-8) occurs, clear
the alarm.
3. Do a complete system purge, following the instruc-
tions under Purging Using Recipe 0, page 56.
4. Shut off the fluid supply to the solvent purge valve
(SPV) and the air supply to the air purge valve
(APV), F
TI12657a
5. With the gun triggered, push the manual override on
the A and B purge valve solenoids to relieve air and
solvent pressure. See F
pressure is reduced to 0.
NOTE: If a Purge Volume alarm (E-11) occurs, clear
the alarm.
. 65.
IG
. 67.
IG
. 65. Verify that solvent
IG
System Operation
51

Advertisement

Table of Contents
loading

Table of Contents