Alarm Troubleshooting
E-15: SYSTEM_IDLE_WARNING
Mix input is high, but the gun has not been triggered for 2
minutes.
E-16: SETUP_CHANGE_WARNING
The system setup parameters have been changed.
E-17: POWER_ON_WARNING
The power to the system has been cycled.
E-18: DEFAULTS_LOADED_WARNING
The factory defaults have been installed on the system.
E-20: PURGE_INITIATE_ALARM
System detects atomizing air to the gun when purge is
selected.
For systems with a gun flush box, gun is not in the box
when purge is selected.
For systems with auto dump on, gun is not in the box
when auto dump is initiated.
80
Table 11. Alarm Troubleshooting
Cause
Cause
Cause
Cause
Cause
Solution
If not painting, clear alarm and resume operation.
If painting, shut down and inspect fluid meter and air flow
switch.
Solution
No action required. See Event Log available through
advanced web interface.
Solution
No action required. See Event Log available through
advanced web interface.
Solution
No action required. See Event Log available through
advanced web interface.
Solution
Shut off gun air.
Place gun in gun flush box. Verify that gun flush box is
operating properly.
Place gun in gun flush box. Verify that gun flush box is
operating properly.