Setup Mode
Advanced Setup Screen 3
F
. 35. Advanced Setup Screen 3
IG
This screen appears only if Flush and Fill Input is set to
"Global" in Option Screen 1, page 31.
If Number of Guns is set to "2" in Configure Screen 4,
page 29, a Gun 2 column will appear in this screen.
First Purge Time
Enter the first purge time (0 to 999 seconds).
Total Chop Time
Enter the total chop time (0 to 999 seconds).
Final Purge Time
Enter the final purge time (0 to 999 seconds).
Mixed Material Fill Time
Enter the mixed material fill time (0 to 999 seconds). It
refers to the amount of material that is required to fill
from the dose valves to the applicator/gun.
34
Advanced Setup Screen 4
F
. 36. Advanced Setup Screen 4
IG
This screen appears only if K-Factor Input is set to
"Global" in Option Screen 1, page 31.
K-factor A Meter
Enter the k-factor (cc/pulse) for flow meter A. This is the
amount of material that passes through the flow meter
per pulse (electrical pulse signal).
K-factor B Meter
Enter the k-factor (cc/pulse) for flow meter B.
K-factor Solvent Meter
This field only appears if Solvent Monitor in Configure
Screen 5, page 30, is set to "Meter." Enter the k-factor
(cc/pulse) for the solvent flow meter.
Advanced Setup Screen 5
F
. 37. Advanced Setup Screen 5
IG
This screen appears only if Flush and Fill Input is set to
"Global" in Option Screen 1, page 31 and Special Out-
puts is set to 1, 2, 3, or 4 in Configure Screen 5, page
30. The I/O board has four programmable outputs.
312776B