E-9: MIX_IN_SETUP_ALARM
Attempt to operate system while in Setup mode.
E-10: REMOTE_STOP_ALARM
Automation has requested that the system abort all oper-
ations.
E-11: PURGE_VOLUME_ALARM
ProMix 2KS solvent flow switch is not activated while
purging.
Minimum flush volume is set too high.
No meter pulses during Color/Catalyst Dump.
E-12: CAN_COMM_ERROR_ALARM
Communication between the Color Change Module and
the Fluid Station is interrupted.
Communication between the Color Change Module and
the Fluid Station is interrupted. The fluid control board
fuse is blown.
Communication between the Booth Control and the Fluid
Station is interrupted.
E-13: HIGH_FLOW_ALARM or E-14: LOW_FLOW_ALARM (may also be set as Warnings)
Fluid system is producing too much or too little flow.
312776B
Table 11. Alarm Troubleshooting
Cause
Cause
Cause
Cause
Cause
Solution
System must be in Standby to change current recipe,
and cannot be operated.
Solution
Abort operations. Troubleshoot automation system.
Solution
Verify that the gun is not shut off and that the solvent flow
switch is activated while purge is taking place.
Increase solvent supply or decrease minimum volume
setting.
Color change solvent supply not set up or functional.
Check Color Change setup.
Solution
Verify that the cable is correctly connected.
Verify condition of fuse and replace if necessary. See
Repair-Parts manual.
Verify that the cable is correctly connected.
Solution
Troubleshoot fluid system for restrictions, leaks,
exhausted fluid supply, incorrect settings, etc. Increase
or decrease flow rate, as required.
Alarm Troubleshooting
79