Graco ProMix 2KS Operation page 43

Plural component proportioner
Hide thumbs Also See for ProMix 2KS:
Table of Contents

Advertisement

5. The components are pre-mixed in the integrator,
then uniformly blended in the static mixer (SM).
NOTE: To control output from the static mixer to the
gun, install an optional fluid pressure regulator.
6. Components A and B are alternately fed into the
integrator as long as the gun is triggered.
Ratio = 2.0:1
A = 2
B = 1
MA
RVA
APV
Key:
MA
Component A Meter
DVA Component A Dose Valve
RVA Component A Sampling Valve
SVA Component A Shutoff Valve
MB
Component B Meter
DVB Component B Dose Valve
RVB Component B Sampling Valve
F
. 51. Wall Mount Fluid Station, Sequential Dosing
IG
312776B
Table 5: Sequential Dosing Operation
Dose 1
DVA
AT
SVA
7. If the gun is not triggered for two minutes, the sys-
tem switches to Idle mode, which closes off the mix
manifold dose valves.
8. When the gun is triggered again, the ProMix 2KS
continues the process where it left off.
NOTE: Operation can be stopped at any time by
pressing the Standby
main power switch.
Dose 2
FI
DVB
SM
SVB
SVB Component B Shutoff Valve
MS
Solvent Meter (accessory)
SPV Solvent Purge Valve
APV Air Purge Valve
SM
Static Mixer
FI
Fluid Integrator
AT
Air Purge Valve Air Supply Tube
System Operation
key or shutting off the
Dose 3
MB
MS
RVB
TI12556a
SPV
43