Shutdown - Graco ProMix PD2K Operation

Electronic positive displacement proportioner
Hide thumbs Also See for ProMix PD2K:
Table of Contents

Advertisement

Operation Using Advanced Display Module (ADM)
Color Change
Change System
System
Color
Color
Change
System
1. Relieve the pressure.
Pressure Relief Procedure, page
2. Attach regulated solvent supply lines as follows:
Multiple color/single
color/single catalyst
• Multiple
Multiple
color/single
color side, do not disconnect the color supply
line from the inlet manifold of Pump A. Instead,
connect a regulated solvent supply line to the
designated solvent valve on the color valve
manifold. On the catalyst side, disconnect
the catalyst supply line from the inlet manifold
of Pump B, and connect a regulated solvent
supply line.
• Multiple
Multiple
Multiple color/multiple
color/multiple
color/multiple catalyst
Connect regulated solvent supply lines to
the designated solvent valves on the color
and catalyst valve manifolds. Do not connect
solvent supply lines directly to the inlet
manifolds of the pumps.
3. Set the solvent supply pressure regulator at the
lowest pressure possible. Generally a setting
of 25–50 psi (0.18–0.35 MPa, 1.8–3.5 bar) is
sufficient.
4. On the ADM, go to the Fill screen. Select Color
(A). Enter the color number in the box to the right.
5. Select the Flush Line box.
6. If the solvent is not already loaded, press the
Prime softkey
solvent into the selected pump and out the outlet
dump valve.
28
See
25.
catalyst system:
system: On the
catalyst
system:
catalyst system:
catalyst
system:
system:
. The system will prime
7. Press the Fill softkey
the selected Color (A) line with the solvent until
the user presses Stop
8. Trigger the applicator until clean solvent
dispenses.
9. Repeat for each color line.
10. Relieve the pressure.
Pressure Relief Procedure, page 25

Shutdown

Shutdown
Shutdown
1. Flush out the mixed material to avoid potlife errors
and fluid setup in the lines. See
2. Follow the
Pressure Relief Procedure, page
3. Close the main air shutoff valve on the air supply
line and on the control box.
4. Press
on the Display Module to turn off
power to the pumps.
5. Shut off system power (0 position).
. The system will flush
.
See
Purging, page
27.
25.
3A4128D