32 PRODIGIT

2-7 Power Up

The following procedure should be followed before applying mains power:
2.7.1. Turn off (O) the POWER switch
2.7.2. Check that the power cord is corrected.
2.7.3. Check that nothing is connected to the DC INPUT on the rear panels.
2.7.4. Turn on POWER switch.

2-8 Connection to the load Input Terminal on the Rear Panel

Connection procedure of the load input terminal on the rear panel
2.8.1 Turn off POWER switch.
2.8.2 Check that the output of the equipment under test is off.
2.8.3 Connect the load wire to the load input terminal on the rear panel.
2.8.4 Check the polarity of the connection and connect the load wire to the output Terminal
Note: Avoid equipment damaged, don't input the DC voltage standard output to the DC Load
input terminal, if calibration voltage meter required, please input the DC voltage standard to the
Vsense input.
2-9 GPIB & RS232 interface option
2.9.1. GPIB + RS232 connector is on the rear panel of 34000A Series Mainframe for
2.9.2. GPIB and RS232 interface can only be used at the same time, to Change the interface
2.9.3. GPIB connection with three important limitations as Described below:
2.9.3.1
2.9.3.2
2.9.3.3
2.9.4. Fig 2-2 shows the RS232 connector (Female) on the rear panel Connects 34000A
Of the equipment under test.
application GPIB or RS232 .
must reboot unit.
The maximum number of devices including the controller is no More than 15.
The maximum length of all cable is no more than 2 meters times The
Number of devices connected together, up to 20 meters Maximum.
RS232 Female Block connections on the back panel, the Connecting Device
and the computer RS232 port to one-way Connection.
(Note: Not 2-wire connection, the detail as 4-2).
Series Mainframe to RS232 port of computer in one By one Configuration .The RS232
BAUD-RATE can be set in the front Panel, it Will be lit the GPIB Address when press
the "SYSTEM" button. Press it again, it will be lit the BAUD-RATE.
Fig 2-2 34000A Series GPIB & RS232 interface