Battery Discharge Test; Fig 5-16 Type 1 Battery Discharge Figure; Fig 5-17 Type 2 Battery Discharge Figure - Prodigit 34000A Series Operation Manual

High power electronic load
Table of Contents

Advertisement

5-17. Battery discharge test

34000A Series battery discharge test, a total of seven types:
5.17.1. TYPE 1:
When testing loads on of Constant current (CC) mode or Constant Power (CP), When
battery voltage is less than UVP (under voltage protect) setting values, The LED is off to
indicate Load off status, and displays the total discharge stored energy of the AH as fig
5-16 shows.
Note: When the remote control, the panel does not show the total discharge capacity.
5.17.2. TYPE2:
When testing loads on of Constant current (CC) mode or Constant Power (CP),, battery
voltage is less than UVP Setting values, Constant current (CC) mode auto change to
Constant voltage (CV) mode as Fig 5-17 shows.
(CV values =UVP setting values).
Note: When CC or CP is converted to CV, there will be a small hardware switching time,
causing the stop to load on. If you do not want to interrupt, refer to 5-7 CC+CV mode or
5-8 CP+CV mode.

Fig 5-16 TYPE 1 Battery Discharge Figure

Fig 5-17 TYPE 2 Battery Discharge Figure

34000A Series Operation Manual 157

Advertisement

Table of Contents
loading

This manual is also suitable for:

34x05a34x10a34x15a34x20a34x25a34x30a ... Show all

Table of Contents