Model
Power
Current
Voltage
Min. Operating Voltage
Protections
Over Power Protection(OPP)
Over Current Protection(OCP)
Over Voltage Protection(OVP)
Over Temp Protection(OTP)
Constant Current Mode
Range
*1
Resolution
Accuracy
Constant Resistance Mode
Range
Resolution
Accuracy
Constant Voltage Mode
Range
Resolution
Accuracy
Constant Power Mode
Range
Resolution
Accuracy
*2
Constant Current Mode + Constant Voltage Mode
Range
Resolution
Accuracy
Constant Power Mode + Constant Voltage Mode
Range
Resolution
Accuracy
MPPT Mode
Algorithm
Load mode
P&O interval
34335A
35KW
0 ~ 35A
0 ~ 1000V
30V @ 350A
105%
104%
104%
YES
35A
0.56mA
3428.4Ω ~ 2.857Ω
2.857Ω ~ 0.02862Ω
5.83uS
± 0.2% of (Setting + Range)
10 ~ 1000V
16mV
3500W
56mW
1000V
16mV
1000V
16mV
Table 1-1A 34000A Series Specification
34000A Series Operation Manual 29
35KW
40KW
0 ~ 350A
0 ~ 40A
350A
5.6mA
0.64mA
± 0.05% of (Setting + Range)
3000Ω ~ 2.5Ω
0.047711mΩ
6.66uS
± 0.05% of (Setting + Range)
35000W
4000W
560mW
64mW
± 0.1% of (Setting + Range)
350A
1000V
5.6mA
16mV
±1.0% of ( setting + Range)
35000W
1000V
560mW
16mV
±1.0% of (Setting + Range)
P&O
CV
1000ms~60000ms ; resolution 1000ms
34340A
40KW
0 ~ 400A
0 ~ 1000V
30V @ 400A
105%
104%
104%
YES
40A
400A
6.4mA
2.5Ω ~ 0.02505Ω
0.04175mΩ
10 ~ 1000V
16mV
40000W
640mW
400A
6.4mA
40000W
640mW