Communication Interface Programming Command Description - Prodigit 34000A Series Operation Manual

High power electronic load
Table of Contents

Advertisement

124 PRODIGIT

4-7. Communication Interface programming command description

4.7.1. PRESET Set and Read the Default of Load
RISE
Syntax:
Purpose: Set and read the RISE SLEW-RATE
Description:
1.
2.
3.
4.
5.
FALL
Syntax : [ PRESet:] FALL {SP}{;NL}
Purpose: Set and read the FALL SLEW-RATE
Description:
1.
2.
3.
PERI or PERD
Syntax : [ PRESet:] PERIPERD:HIGHLOW{SP}{ NR2}{;NL}
Purpose: Set and read the TLOW and Thigh of DYNAMIC when loading
Description:
1.
2.
3.
4.
5.
LDONv
Syntax: [ PRESet:] LDONv {SP}{NR2}{;NL}
Purpose: Set and Read the voltage of LOAD ON
Description:This command is for setting the Load voltage value of LOAD ON.
[PRESet:] RISE {SP}{NR2}{;NL}
[PRESet:] RISE? {;NL}
The definition of RISE SLEW-RATE is load level change or dynamic load can be
Programmed of RISE and FALL are completely independent.
The value of RISE has to be included the number of the decimal point, otherwise
The command will not be available.
The least significant number is the 3th behind the decimal point.
34000A Series will set to the maximum value of the model automatically when
The set RISE is over the specification of Load.
The unit is A/uS.
[PRESet:] FALL? {;NL}
The definition of FALL SLEW-RATE is load level change or dynamic load can be
Programmed of RISE and FALL are completely independent.
34000A Series will set to the maximum value of the model automatically when
the FALL which has been set is over the specification of Load.
The unit is A/uS.
[ PRESet:] PERIPERD:HIGHLOW?{;NL}
A period of loading waveform of DYNAMIC is combined by TLOW and THIGH.
The value of TLOW and THIGH have to be included the number of the decimal
Point, otherwise the command will not be available.
The least significant number is the 5th behind the decimal point.
34000A Series will set the value of TLOW or THIGH automatically when the
Value which has been set is over the maximum of the Load.
The unit is mS.
[ PRESet:] LDONv?{;NL}

Advertisement

Table of Contents
loading

This manual is also suitable for:

34x05a34x10a34x15a34x20a34x25a34x30a ... Show all

Table of Contents