5-13. Power Supply OCP testing
5.13.1 OCP Manual control
Example:
5.13.1.1. First, press Limit Key function to setting I_Hi & I_Lo.
5.13.1.2. Setting OCP test, press OCP key to the next step.
CC
CR
5.13.1.3. Setting start load current 0A, press OCP key to the next step.
CC
CR
5.13.1.4. Setting step load current 0.01A, press OCP key to the next step.
CC
CR
5.13.1.5. Setting stop load current 5A, press OCP key to the next step.
CC
CR
34210A
600V/320A,10KW DC ELECTRONIC LOAD
CV
CP SEQ.
Range
DYN STA
II
V
34210A
600V/320A,10KW DC ELECTRONIC LOAD
Range
CV
CP SEQ.
DYN STA
V
34210A
600V/320A,10KW DC ELECTRONIC LOAD
Range
CV
CP SEQ.
DYN STA
V
34210A
600V/320A,10KW DC ELECTRONIC LOAD
CV
CP SEQ.
DYN STA
V
34000A Series Operation Manual 147
LAN USB
Range
RS232
LEV
LEV
HI
LO
Auto
A
Range
LAN USB
LEV
LEV
HI
LO
II
Auto
A
Range
LAN USB
LEV
LEV
HI
LO
II
Auto
A
Range
Range
LAN USB
LEV
LEV
HI
LO
II
Auto
A
NG
GPIB REM
W
V
mS
A
NG
GPIB REM
RS232
W
V
mS
A
NG
GPIB REM
RS232
W
V
mS
A
NG
GPIB REM
RS232
W
V
mS
A