Power Supply Ocp Testing - Prodigit 34000A Series Operation Manual

High power electronic load
Table of Contents

Advertisement

5-13. Power Supply OCP testing

5.13.1 OCP Manual control
Example:
5.13.1.1. First, press Limit Key function to setting I_Hi & I_Lo.
5.13.1.2. Setting OCP test, press OCP key to the next step.
CC
CR
5.13.1.3. Setting start load current 0A, press OCP key to the next step.
CC
CR
5.13.1.4. Setting step load current 0.01A, press OCP key to the next step.
CC
CR
5.13.1.5. Setting stop load current 5A, press OCP key to the next step.
CC
CR
34210A
600V/320A,10KW DC ELECTRONIC LOAD
CV
CP SEQ.
Range
DYN STA
II
V
34210A
600V/320A,10KW DC ELECTRONIC LOAD
Range
CV
CP SEQ.
DYN STA
V
34210A
600V/320A,10KW DC ELECTRONIC LOAD
Range
CV
CP SEQ.
DYN STA
V
34210A
600V/320A,10KW DC ELECTRONIC LOAD
CV
CP SEQ.
DYN STA
V