Table 4-7 Auto Sequence Command List; Table 4-8 Battery Test Set Command - Prodigit 34000A Series Operation Manual

High power electronic load
Table of Contents

Advertisement

AUTO SEQUENCE:
AUTO SEQUENCE SET COMMAND
FILE {SP} {n}{; NL}
STEP {SP} {n} {;NL}
TOTSTEP {SP} {n}{;NL}
SB {SP} {m} {;NL}
TIME {SP} {NR2} {;NL}
SAVE {;NL}
REPEAT {SP} {n} {;NL}
RUN {SP} {F} {n} {;NL}
BATTERY TEST SET COMMAND
COMMAND
BATT:TYPE {SP}{n}{;NL}
BATT:UVP{SP}{NR2}{;NL}
BATT:TIME{SP}{NR1}{;NL }
BATT:STEP{SP} {n} {;NL}
BATT:CCH{n}{SP} {NR2} {;NL}
BATT:CCL{n}{SP} {NR2} {;NL}
BATT:TH{n}{SP} {NR2} {;NL}
BATT:TL{n}{SP} {NR2} {;NL}
BATT:CYCLE{n}{SP} {NR1} {;NL}
BATT:CC{n}{SP} {NR2} {;NL}
BATT:DTIME{n}{SP} {NR2} {;NL}
BATT:REPEAT {SP} {NR1}{;NL}
BATT:TEST {SP} {ON|OFF}{;|NL}

Table 4-7 Auto sequence command list

MODEL
34XXXA

Table 4-8 BATTERY TEST SET COMMAND

34000A Series Operation Manual 117
NOTE
n=1~9
n=1~16
Total step n=1~16
m=1~150
m:STATE
100~9999(ms)
Save "File n" data
n=0~9999
N=1~9
V
n=1~5
V
unit:V
V
TIME= 1~99999sec
V
TYPE4:n=1~3,TYPE5:n=1~9
V
TYPE4 CC:HIGH level, n=1~3
V
TYPE4 CC:LOW level, n=1~3
V
TYPE4 Thigh(unit:ms), n=1~3
V
TYPE4 Tlow(unit:ms), n=1~3
V
TYPE4 Cycle:1~2000, n=1~3
V
TYPE5 Current, n=0~9
TYPE5
Delta
V
n=0~9
V
TYPE4&5 Repeat times:0~9999
ON:START TEST,OFF:STOP TEST
TYPE1&2 TEST END,AUTO ECHO
V
"OK,XXXXX" XXXXX:AH
TYPE3~5 TEST END,AUTO ECHO
"OK,XXXXX" XXXXX:DVM
RETURN
1~9
1~16
1~16
100~9999(ms)
0~9999
AUTO REPLY
"PASS" or "FAIL:XX"
(XX=NG STEP)
REMARK
time(T1~T9:0~6000sec),

Advertisement

Table of Contents
loading

This manual is also suitable for:

34x05a34x10a34x15a34x20a34x25a34x30a ... Show all