Exchange Of The Solenoid Valve / Replacement Of The Flow Regulator; Replacement Of The Connecting Tube - Water Separation & Output; Fig. 13.2 Solenoid Valve Replacement; Fig. 13.3 Flex Tube - Ecolab DG 3.1 Operating Instructions Manual

Stationary metering unit for instrument and surface disinfectant
Table of Contents

Advertisement

Available languages

Available languages

13.3.2

Exchange of the Solenoid Valve / Replacement of the Flow Regulator

The Flow Regulator is already included in a replacement solenoid valve and, in this case,
NOTE
does not need to be replaced. Exception: If metering is set at 10 %, the flow regulator must
also be replaced in a new replacement solenoid valve.
The solenoid valve and / or flow regulator are to be replaced as follows:
 Pull out the mains plug and interrupt the water infeed (close the angle valve).
 Pull out plug (Item 1) and loosen nut (Item 2)
 Loosen swivel nuts (Item 3), remove solenoid valve (Item 4)
 Remove old flow regulator (Item 5) with a suitable tool
 Insert the new flow regulator (Item 6). You must make sure that the new flow regulator is
positioned correctly (see chapter 11.1, Fig. 11.1).
 Reinstall the solenoid valve in reverse order.
Ensure that the flat seal is correctly seated.
 Reconnect the electricity and water supply.
 Check that the device is functioning properly and make sure that it is not leaking.
13.3.3
Replacement of the Connecting Tube - Water Separation & Output
In the event of microbial contamination or to prevent this occurring, the flexible stainless
steel tube (flex tube) (see Fig. 13.2) must be replaced.
417102242_DG_3
Item
1
2
3
4
5
6
Fig. 13.2
Item
Description
1
Connecting tube
2
Swivel nuts
Fig. 13.3
Flex tube
Procedure:
 Loosen both swivel nuts (Item 2).
 Remove the connecting tube (Item 1).
 Screw on the new tube and ensure that the flat seals are
correctly seated.
 Start the device and check for leaks.
Fig. 13.4
Solenoid valve replacement
- 96 -
Description
Plug
Nut
Swivel nut
Solenoid valve
Old flow regulator
New flow regulator
Solenoid valve replacement
Flex tube G½ – 0.26 m
with a flat seal (2 x)
Rev.: 02-05.2014